34
The mains voltage must not be interrupted (e.g. via a light switch).
If the control sensor does not have a permanent power connection,
/
a possible leak may not be identified,
/
the control sensor cannot close in the event of a leak.
5.4
INSTALLATION DIMENSIONS
The control sensor can be installed in horizontal or vertical pipes.
Fig. 3: Installation dimensions
Installation dimensions for
combination
of the control sensor
with the following filters
CLEAR 2.0 K
CLEAR 2.0 KD
¾" - 1"
CLEAR 2.0 K
CLEAR 2.0 KD
1¼"
CLEAR 2.0 R
CLEAR 2.0 RD
¾" - 1"
CLEAR 2.0 R
CLEAR 2.0 RD
1¼"
B: Device width
173
173
173
173
E: Depth to pipe middle
257
262
257
262
F: Waste water connector middle
to pipe middle
--
--
197
202
All dimensions in [mm]