Jump
- 332970E_A005
04/03/21
- 63 -
FR
EN
6.3.2- Jump «Battery» version
A
B
LD1
LD5
LD2
LD3
LD4
CHARGE
ERROR
CONFIG
ERROR
CONFIGURATION
TENS
UNITS
Batterie PYB
LED
Color
Function
State
Description
LD1
RED
Battery charge
error
Off
No battery charge error
On steady
Battery charge error (Electronic fault or inappropriate
charging temperatures)
LD2
GREEN
Radio signal
reception
Off
No radio signal received or reception of incorrect radio
frame
On steady
Radio signal reception with correct frames
Flashing
Low radio reception rate with correct frames
LD3
RED
Indicates internal
battery endurance
Off
ON/OFF pushbutton set to OFF
On steady
or internal battery entirely discharged
1 flash
Internal battery endurance > 90%
2 flashes
(ON/OFF pushbutton set to ON)
Fast flashing
Internal battery endurance between 90% and 50%
LD2 +
LD3
GREEN +
RED
During the learning
transmitter identity
code procedure
Synchronized
continuous flashes
The repeater is waiting for a radio signal from the
transmitter to «learn» the identity code
Flashes alternately
The identity code is «learned»
LD4
YELLOW
Internal battery
charge
Off
No external power supply on M12 connector
On steady
Battery charged
Flashing
Battery charging in progress
LD5
RED
Radio channel
configuration error
Off
No configuration error
On steady
Radio channel configuration channel detected
Flashing
The repeater is configured with the radio operating
mode nb 2 (reception radio channel is different from
transmission radio channel)
Содержание Jay Electronique Jump
Страница 2: ...2 Jump 332970E_A005 04 03 21...
Страница 30: ...30 Jump 332970E_A005 04 03 21 FR EN 11 Dimensions dimensions en mm...
Страница 40: ...40 Jump 332970E_A005 04 03 21 FR EN...
Страница 41: ...Jump 332970E_A005 04 03 21 41 FR EN...
Страница 69: ...Jump 332970E_A005 04 03 21 69 FR EN 11 Dimensions dimensions in mm...
Страница 79: ...Jump 332970E_A005 04 03 21 79...
Страница 80: ...80 Jump 332970E_A005 04 03 21...