![Concoa IntelliSwitch 57 Series Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/concoa/intelliswitch-57-series/intelliswitch-57-series_maintenance-instructions-manual_2651328011.webp)
11
Figure 4
It is possible to switch back to the other delivery regulator and change its pressure by pushing the Output Source PB again.
The delivery pressure for both regulators should be the same to within 1-2 PSI for best performance.
8.
When the desired delivery pressure for both regulators is set, turn OFF SW4-4 on the control board. See Figure 4.
9.
Locate SW5 on the control board (Figure 3) and press it once. The system should go back to normal operation showing
inlet pressures on both inlet displays.
10.
Calibration is complete. Close door and re-attach screws.