47
PDV 7360, 7377
EN
8. Prior in installation to the board, secure the appliance’s bottom perimeter using a watertight seal.
9. Position the unit onto the edge of the board and pass the power cord through the opening so that the plug or
terminals remain accessible after installation.
10. Push the unit carefully into place. Be careful not to squeeze the power cord.
11. Connect the gas supply pipe or hose to the appliance (refer to the Gas supply connection).
12. Screw the 4 bottom fasteners to mount the appliance on the cabinet.
13. Connect the lead-in cord to the wall outlet or terminal box (refer to Connecting to the mains).
Removal
To uninstall the unit, it is important to proceed correctly:
1. First, unplug the power cord from the mains (pull out the plug or switch off the circuit breaker).
2. Shut-off the gas valve.
3. Remove the attachment screws.
4. Remove the appliance and carefully disconnect the gas supply as well as the power cord.
TROUBLESHOOTING
Problem
Cause
Solution
The piezo-electric ignitors of all
burners do not operate.
Power cord is improperly connected
or power has failed.
Check the connection and electricity.
The burner extinguishes after
being lit.
The control knob of the burner was
not pressed long enough to allow
the thermocouple to warm up, so the
protection was not deactivated.
Keep the knob pressed longer (up to 15
seconds, maximum).
The piezo-electric ignitor of
a burner does not operate.
The ignitor is blocked by dirt, food, or
cleaner remnants.
Thoroughly clean the burner and the area
around the piezo-electric ignitor.
The burner is clogged.
Dismantle and clean the burner.
The burner is wet.
Thoroughly dry the burner and the area
around the piezo-electric ignitor.
The burner is incorrectly assembled.
Check the burner assembly.
The burner flame is not
uniform.
The burner is incorrectly assembled.
Check the burner assembly.
Clogged burner outlets.
Clean the burner outlets.
Gas is smelled in the room.
Connection leakage.
Check the connection or call for an
inspection.
Thermocouple malfunction.
Call your authorized service body for an
inspection.