Corporate Office: 724.584.5500
Instant Access 24/7 (Parts and Service): 800.458.1960
Parts and Service
:
814.437.6861
37
Table 13 – ESEW & ESER Single-Circuit Chiller Electrical Data (60 Hz)
Model
Main Power (3-phase, 60 Hz)
Compressors
Chiller
Rated
Allowable
Qty
RLA
1
LRA
2
MCA
3
MOPD
4
Min
Max
(each)
(each)
ESEW-010S
& ESER-010S
208
187
253
2
19.0
123
43
60
230
187
253
2
19.0
123
43
70
460
414
508
2
9.7
62
22
35
575
518
632
2
7.4
50
18
25
ESEW-015S
& ESER-015S
208
187
253
2
29.5
195
67
110
230
187
253
2
29.5
195
67
110
460
414
508
2
14.7
95
34
50
575
518
632
2
12.2
80
29
45
ESEW-020S
& ESER-020S
208
187
253
2
33.3
239
76
125
230
187
253
2
33.3
239
76
125
460
414
508
2
17.9
125
42
60
575
518
632
2
12.8
80
30
45
ESEW-025S
& ESER-025S
208
187
253
2
51.3
300
117
175
230
187
253
2
51.3
300
117
175
460
414
508
2
23.1
150
53
80
575
518
632
2
19.9
109
46
70
ESEW-030S
& ESER-030S
208
187
253
2
55.8
340
127
200
230
187
253
2
55.8
340
127
200
460
414
508
2
26.9
173
62
100
575
518
632
2
23.7
132
55
80
ESEW-040S
& ESER-040S
208
187
253
2
72.4
538
164
250
230
187
253
2
72.4
538
164
250
460
414
508
2
30.8
229
71
110
575
518
632
2
25.0
180
58
90
ESEW-050S
& ESER-050S
208
187
253
2
85.3
605
193
300
230
187
253
2
85.3
605
193
300
460
414
508
2
37.8
320
86
125
575
518
632
2
34.6
250
79
125
ESEW-060S
& ESER-060S
208
187
253
2
109.6
599
248
400
230
187
253
2
109.6
599
248
400
460
414
508
2
54.5
310
124
200
575
518
632
2
49.4
239
112
175
ESEW-080S
& ESER-080S
208
187
253
2
N/A
N/A
N/A
N/A
230
187
253
2
N/A
N/A
N/A
N/A
460
414
508
2
73.0
368
165
250
575
518
632
2
N/A
N/A
N/A
N/A
1
RLA is Rated Load Amps.
2
LRA is Locked Rotor Amps.
3
MCA is Minimum Circuit Amps (for wire sizing), complies with NEC, Section 430-24.
4
MOPD is Maximum Over-current Protection Device, complies with NEC, Section 430-53.