88
Error Codes and System Messages
CAPI3000 I214:
ASI Disconnect Indication: Virtual Server aaaaaaaa/
Port p: Received with no discernible cause.
The above console output is generated when the
operator selects the VS3000 configuration utility
diagnostic option for Event Logging and a
Nb_DISCONNECT Indicate message from VS3000
aaaaaaaa, port p, had no disconnect reason code.
CAPI3000 I300:
Virtual Server aaaaaaaa/Port p/Bn: Incoming call
from servername ignored by Application IDn.
Application returned an “ignore call.” Normally this
allows other devices on an S/T bus to answer the call;
however, this event may mean a discrepancy between
the configuration of the VS3000 SPIDs and DNs and
the configuration of the application. The VS3000 port
will be tied up until a timeout cleans up the call.
CAPI3000 I301:
Virtual Server aaaaaaaa/Port p/Bn: Incoming call
ignored by Application IDn.
Application returned an “ignore call.” Normally this
allows other devices on an S/T bus to answer the call;
however, this event may mean a discrepancy between
the configuration of the VS3000 SPIDs and DNs and
the configuration of the application. The VS3000 port
will be tied up until a timeout cleans up the call.
CAPI3000 I800:
VS3000 [00C04E0xyyyy] aaaaaaaa (#dd) reconfigure
pending.
The above console output is generated when the
operator reconfigures VS3000 aaaaaaaa at MAC
address 00C04E0xyyyy while that VS3000 is active.
Table 7. CAPI3000 Informational Codes
Code
Message and Description