CDM-800 Gateway Router
Revision 1
Installation
MN-CDM800
2–2
Once
opened,
inspect
the
shipment:
Step
Task
1
Keep
all
shipping
materials
for
storage
or
reshipment.
2
Check
the
packing
list
to
ensure
the
shipment
is
complete.
3
Inspect
the
equipment
for
any
possible
damage
incurred
during
shipment.
Contact
the
carrier
and
Comtech
EF
Data
immediately
to
submit
a
damage
report
if
damage
is
evident.
4
Review
this
CDM
‐
800
Gateway
Router
Installation
and
Operation
Manual
carefully
to
become
familiar
with
operation.
5
Proceed
to
Sect.
2.2
Installation
into
a
Rack
Enclosure.
2.2
Installation into a Rack Enclosure
When
mounting
the
CDM
‐
800
into
a
rack
enclosure
(Figure
2
‐
2):
•
PROPER
GROUNDING
PROTECTION
IS
REQUIRED.
The
equipment
must
be
connected
to
the
protective
earth
connection
at
all
times.
It
is
therefore
imperative
that
the
unit
is
properly
grounded,
using
the
ground
stud
provided
on
the
unit
rear
panel,
during
installation,
configuration,
and
operation.
•
PROPER
AIR
VENTILATION
IS
REQUIRED.
In
a
rack
system
where
there
is
high
heat
discharge,
provide
forced
‐
air
cooling
with
top
‐
or
bottom
‐
mounted
fans
or
blowers.
o
Make
sure
there
is
adequate
clearance
inside
the
enclosure,
especially
at
the
side
for
air
ventilation.
o
Air
temperature
inside
the
rack
enclosure
should
never
exceed
50
°
C
(122
°
F).
For
information
about
custom
rack
enclosures,
contact
Comtech
EF
Data
Customer
Support
during
normal
business
hours
or
visit
Comtech
EF
Data’s
Web
site
(www.comtechefdata.com/support.asp).
•
The
CDM
‐
800
CANNOT
have
rack
slides
mounted
to
the
sides
of
the
chassis.
Cooling
fans
and
exhaust
vents
are
provided
here
–
air
flow
must
not
be
impeded.
Comtech
EF
Data
recommends
that
an
alternate
method
of
support
is
provided
within
the
rack,
such
as
standard
rack
shelves
or
the
optional
Rear
‐
Mounting
Support
Bracket
Kit.
If
there
is
any
doubt,
contact
Comtech
EF
Data
Customer
Support
during
normal
business
hours.
Содержание CDM-800
Страница 2: ......
Страница 4: ...This page is intentionally blank...
Страница 20: ...CDM 800 Gateway Router Revision 1 Preface MN CDM800 xviii Notes...
Страница 30: ...CDM 800 Gateway Router Revision 1 Introduction MN CDM800 1 10 Notes...
Страница 36: ...CDM 800 Gateway Router Revision 1 Installation MN CDM800 2 6 Notes...
Страница 108: ...CDM 800 Gateway Router Revision 1 Ethernet based Remote Product Management MN CDM800 5 48 Notes...
Страница 120: ...CDM 800 Gateway Router Revision 1 Serial based Remote Product Management MN CDM800 6 12 Notes...
Страница 125: ...CDM 800 Gateway Router Revision 1 Appendix B MN CDM800 B 3 Figure B 1 DVB S2 QPSK Packet Error Rate versus Es No...
Страница 126: ...CDM 800 Gateway Router Revision 1 Appendix B MN CDM800 B 4 Figure B 2 DVB S2 8PSK Packet Error Rate versus Es No...
Страница 127: ...CDM 800 Gateway Router Revision 1 Appendix B MN CDM800 B 5 Figure B 3 DVB S2 16APSK Packet Error Rate versus Es No...
Страница 128: ...CDM 800 Gateway Router Revision 1 Appendix B MN CDM800 B 6 Figure B 4 DVB S2 32APSK Packet Error Rate versus Es No...
Страница 130: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...