CDM-800 Gateway Router
Revision 1
Serial-based Remote Product Management
MN-CDM800
6–8
6.3
Remote Commands and Queries
The
Serial
Command
Line
interface
(CLI)
(the
Controller),
shown
previously
in
Figure
5
‐
1
,
is
used
to
issue
remote
commands
and
queries
to
the
CDM
‐
800
(the
Target).
From
the
CLI
command
prompt
CDM
‐
800>
type
in
the
command
or
query
packet,
using
the
format
explained
previously,
for
transmission
to
the
CDM
‐
800.
For
example:
CDM
‐
800><0000/LC1=3[cr]
The
table
that
follows
provides
a
‘quick
reference‘
to
the
Instruction
Codes
available
at
present
for
M&C
of
the
CDM
‐
800.
The
‘
C
’
and
‘
Q
’
columns,
when
marked
with
an
‘
X
’,
denote
whether
that
Instruction
Code
is
Command
Only
,
Query
Only
,
or
Command
and
Query
.
INSTRUCTION
CODE
USED
TO...
C
Q
Page
DPW
Set
default
passwords
X
5
‐
9
IG1
Set
or
query
the
IP
Address
and
network
prefix
for
the
GE
‐
1
10/100/1000
Gigabit
Ethernet
Port
X
X
5
‐
9
IG2
Set
or
query
the
IP
Address
and
network
prefix
for
the
GE
‐
2
10/100/1000
Gigabit
Ethernet
Port
X
X
5
‐
10
IPA
Set
or
query
the
IP
Address
and
network
prefix
for
the
FE
(10/100
Fast
Ethernet)
port
X
X
5
‐
10
LC1
Set
or
query
the
link
configuration
for
the
GE
‐
1
10/100/1000
Gigabit
Ethernet
Port
X
X
5
‐
10
LC2
Set
or
query
the
link
configuration
for
the
GE
‐
2
10/100/1000
Gigabit
Ethernet
Port
X
X
5
‐
10
MAC
Query
the
unique
router
MAC
Address
X
5
‐
11
MG1
Query
the
unique
GE
‐
1
port
MAC
Address
X
5
‐
11
MG2
Query
the
unique
GE
‐
2
port
MAC
Address
X
5
‐
11
MLC
Set
or
query
the
link
configuration
for
the
FE
Port
X
X
5
‐
11
NPS
Query
the
negotiated
port
speeds
for
the
GE
‐
1,
GE
‐
2,
and
FE
ports
X
5
‐
11
SRC
Set
or
query
the
SNMP
Read
Community
String
X
X
5
‐
11
SWC
Set
or
Query
the
SNMP
Write
Community
String
X
X
5
‐
11
Содержание CDM-800
Страница 2: ......
Страница 4: ...This page is intentionally blank...
Страница 20: ...CDM 800 Gateway Router Revision 1 Preface MN CDM800 xviii Notes...
Страница 30: ...CDM 800 Gateway Router Revision 1 Introduction MN CDM800 1 10 Notes...
Страница 36: ...CDM 800 Gateway Router Revision 1 Installation MN CDM800 2 6 Notes...
Страница 108: ...CDM 800 Gateway Router Revision 1 Ethernet based Remote Product Management MN CDM800 5 48 Notes...
Страница 120: ...CDM 800 Gateway Router Revision 1 Serial based Remote Product Management MN CDM800 6 12 Notes...
Страница 125: ...CDM 800 Gateway Router Revision 1 Appendix B MN CDM800 B 3 Figure B 1 DVB S2 QPSK Packet Error Rate versus Es No...
Страница 126: ...CDM 800 Gateway Router Revision 1 Appendix B MN CDM800 B 4 Figure B 2 DVB S2 8PSK Packet Error Rate versus Es No...
Страница 127: ...CDM 800 Gateway Router Revision 1 Appendix B MN CDM800 B 5 Figure B 3 DVB S2 16APSK Packet Error Rate versus Es No...
Страница 128: ...CDM 800 Gateway Router Revision 1 Appendix B MN CDM800 B 6 Figure B 4 DVB S2 32APSK Packet Error Rate versus Es No...
Страница 130: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...