CDM-800 Gateway Router
Revision 1
Serial-based Remote Product Management
MN-CDM800
6–10
Parameter
Type
Command
(Instruction
& Qualifier)
Number of
Arguments
Description of Arguments
Response to
Command
Query
(Instruction &
Qualifier)
Response to Query
GE2 Address
IG2=
18 bytes numerical Command or Query.
Sets the IP Address and network prefix for the 10/100/1000 BaseT GE2 Ethernet
port, in the form aaa.bbb.ccc.ddd/yy, where:
(Permitted ranges – cannot all be zero)
aaa = 0-223
bbb = 0-255
ccc = 0-255
ddd = 0-255
yy = network prefix (range: 8 to 31)
Other restrictions:
If aaa>191, prefix may not be less than 24.
If aaa>127, prefix may not be less than 16.
Example: IG2=010.006.030.001/24
IG2=
IG2?
IG2*
IG2#
IG2?
IG2=xxx.xxx.xxx.xxx/yy
(see Description of Arguments)
Management IP
Address
IPA=
18 bytes numerical Command or Query.
Sets the IP Address and network prefix for the 10/100 Base T Ethernet
management port, in the form aaa.bbb.ccc.ddd/yy, where:
(Permitted ranges – cannot all be zero)
aaa = 0-223
bbb = 0-255
ccc = 0-255
ddd = 0-255
yy = network prefix (range: 8 to 31)
Example: IPA=010.006.030.001/24
IPA=
IPA?
IPA*
IPA#
IPA?
IPA=xxx.xxx.xxx.xxx/yy
(see Description of Arguments)
GE1 Link
Configuration
LC1=
1 byte, value 0 thru
5
Command or Query.
GE1 Interface mode, where:
0 = Auto Negotiate
1 = 1000Mbps -Full Duplex
2 = 100Mbps – Full Duplex
3 = 100Mbps – Half Duplex
4 = 10Mbps – Full Duplex
5 = 10Mbps – Half Duplex
LC1=
LC1?
LC1*
LC1#
LC1?
LC1=x
(see Description of Arguments)
GE2 Link
Configuration
LC2=
1 byte, value 0 thru
5
Command or Query.
GE2 Interface mode, where:
0 = Auto Negotiate
1 = 1000Mbps -Full Duplex
2 = 100Mbps – Full Duplex
3 = 100Mbps – Half Duplex
4 = 10Mbps – Full Duplex
5 = 10Mbps – Half Duplex
LC2=
LC2?
LC2*
LC2#
LC2?
LC2=x
(see Description of Arguments)
Содержание CDM-800
Страница 2: ......
Страница 4: ...This page is intentionally blank...
Страница 20: ...CDM 800 Gateway Router Revision 1 Preface MN CDM800 xviii Notes...
Страница 30: ...CDM 800 Gateway Router Revision 1 Introduction MN CDM800 1 10 Notes...
Страница 36: ...CDM 800 Gateway Router Revision 1 Installation MN CDM800 2 6 Notes...
Страница 108: ...CDM 800 Gateway Router Revision 1 Ethernet based Remote Product Management MN CDM800 5 48 Notes...
Страница 120: ...CDM 800 Gateway Router Revision 1 Serial based Remote Product Management MN CDM800 6 12 Notes...
Страница 125: ...CDM 800 Gateway Router Revision 1 Appendix B MN CDM800 B 3 Figure B 1 DVB S2 QPSK Packet Error Rate versus Es No...
Страница 126: ...CDM 800 Gateway Router Revision 1 Appendix B MN CDM800 B 4 Figure B 2 DVB S2 8PSK Packet Error Rate versus Es No...
Страница 127: ...CDM 800 Gateway Router Revision 1 Appendix B MN CDM800 B 5 Figure B 3 DVB S2 16APSK Packet Error Rate versus Es No...
Страница 128: ...CDM 800 Gateway Router Revision 1 Appendix B MN CDM800 B 6 Figure B 4 DVB S2 32APSK Packet Error Rate versus Es No...
Страница 130: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...