CDM-740 Advanced Satellite Modem
Revision 0
Front Panel Operation
MN-CDM740
5–8
5.4.1.6 (CONFIG:) Tx
Æ
Data
Tx Data Rate: 9980.000 kbps
Tx Symbol Rate: 2851.429 ksps
(
◄►
E)
To configure the
Tx Data Rate
(in kbps), on the top line select the digit of Data Rate to be edited
using the
◄
►
arrow keys, then change the value of that digit using the
▲
▼
arrow keys. Press
ENTER
when done.
The maximum limits for the Tx Data Rate are
16 kbps
to
9.98 Mbps
. The resolution is
1 bps
.
The actual minimum and maximum data rates are dependent on Framing mode, Interface type,
Modulation type and FEC Code Rate. If the user changes any of the higher-priority parameters –
causing the data rate to become invalid – the
Tx Data Rate
is adjusted automatically. The upper
range of data rate will also be dictated by the FAST option(s) installed.
To configure the
Tx Symbol Rate
(in ksps), on the bottom line select the digit of Symbol Rate to
be edited using the
◄
►
arrow keys. Change the value of that digit using the
▲
▼
arrow keys,
then press
ENTER
.
Refer to
Table 5-1
for Tx Symbol Rate and Data Rate ranges (TPC).
Table 5-1. Tx Symbol Rate / Data Rate Ranges – TPC
Modulation
FEC Code
Code Rate
Symbol Rate (Ksps)
Spectral
Efficiency
Data Rate (Kbps)
Min
Max
Min
Max
QPSK Turbo
21/44 16.762 2996.190 0.955 16.000 2860.000
3/4 10.667 3000.000 1.500 16.000 4500.000
7/8 9.143
3000.000
1.750
16.000
5250.000
0.95 8.421
2982.105
1.900 16.000
5666.000
8-QAM Turbo
3/4 7.111
3000.000
2.250
16.000
6750.000
7/8 6.095
3000.000
2.625
16.000
7875.000
0.95 5.614
2982.456
2.850 16.000
8500.000
16-QAM Turbo
3/4 5.333
3000.000
3.000
16.000
9000.000
7/8 4.800
2851.429
3.500
16.800
9980.000
5.4.1.7 (CONFIG:) Tx
Æ
Scrambler
Tx Scrambler: Off Normal IESS
(
◄►
E)
Select
Off
,
Normal
, or
IESS
using the
◄
►
arrow keys, then press
ENTER.
Note the following:
•
When
Normal
is selected, the TPC scrambler is used.
•
When
IESS
is selected, the default ITU V.35 scrambler specified is used.
Содержание CDM-740
Страница 2: ......
Страница 8: ...This page is intentionally blank...
Страница 16: ...CDM 740 Advanced Satellite Modem Revision 0 Table of Contents MN CDM740 x This page is intentionally blank...
Страница 24: ...CDM 740 Advanced Satellite Modem Revision 0 Preface MN CDM740 xviii Notes...
Страница 38: ...CDM 740 Advanced Satellite Modem Revision 0 Introduction MN CDM740 1 14 Notes...
Страница 42: ...CDM 740 Advanced Satellite Modem Revision 0 Installation MN CDM740 2 4 Notes...
Страница 84: ...CDM 740 Advanced Satellite Modem Revision 0 Front Panel Operation MN CDM740 5 32 Notes...
Страница 114: ...CDM 740 Advanced Satellite Modem Revision 0 Ethernet Management MN CDM740 6 30 Notes...
Страница 138: ...CDM 740 Advanced Satellite Modem Revision 0 Remote Control MN CDM740 A 24 Notes...
Страница 150: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...