CDM-740 Advanced Satellite Modem
Revision 0
Installation
MN-CDM740
2–2
2.2
Mounting
If the CDM-740 is to be mounted in a rack, ensure that there is adequate clearance for ventilation,
particularly at the sides. In rack systems where there is high heat dissipation, forced air cooling
must be provided by top or bottom mounted fans or blowers. Under no circumstance should the
highest internal rack temperature be allowed to exceed 50°C (122°F).
IMPORTANT
The CDM-740 CANNOT have rack slides mounted to the side of the chassis.
Three cooling fans are mounted in the left-hand side of the unit. Comtech EF Data
recommends that an alternate method of support within the rack be employed, such
as rack shelves or the optional rear support brackets. If there is any doubt, please
consult the Comtech EF Data Customer Support department.
2.2.1 Optional Rear-Mounting Support Bracket Installation
Install optional rear-mounting support brackets using mounting kit KT/6228-2:
Quantity
Part Number
Description
2
HW/10-32SHLDR
Screw, #10 Shoulder
4
HW/10-32FLT
Washer, #10 Flat
2
HW/10-32SPLIT
Washer, #10 Split
2
HW/10-32HEXNUT
Nut, #10 Hex
2
FP/6138-1
Bracket, Rear Support
4
HW/10-32x1/2RK
Bolt, #10 Rack Bracket
The tools required for this installation are a
medium
Phillips
™
screwdriver
and a
5/32-inch
SAE
Allen
™
Wrench.
The kit is installed as illustrated in
Figure 2-1
via the following procedure:
Step
Procedure
1
Secure the #10 shoulder screws to the unit chassis through the rear right and left side
mounting slots, using the #10 flat washers, #10 split washers, and #10 hex nuts as
shown.
2
Install the rear support brackets onto the equipment rack threaded rear mounting
rails, using the #10 rack bracket bolts.
3
Mount the unit into the equipment rack, ensuring that the shoulders of the #10 shoulder
screws properly engage into the rear support bracket slots.
Содержание CDM-740
Страница 2: ......
Страница 8: ...This page is intentionally blank...
Страница 16: ...CDM 740 Advanced Satellite Modem Revision 0 Table of Contents MN CDM740 x This page is intentionally blank...
Страница 24: ...CDM 740 Advanced Satellite Modem Revision 0 Preface MN CDM740 xviii Notes...
Страница 38: ...CDM 740 Advanced Satellite Modem Revision 0 Introduction MN CDM740 1 14 Notes...
Страница 42: ...CDM 740 Advanced Satellite Modem Revision 0 Installation MN CDM740 2 4 Notes...
Страница 84: ...CDM 740 Advanced Satellite Modem Revision 0 Front Panel Operation MN CDM740 5 32 Notes...
Страница 114: ...CDM 740 Advanced Satellite Modem Revision 0 Ethernet Management MN CDM740 6 30 Notes...
Страница 138: ...CDM 740 Advanced Satellite Modem Revision 0 Remote Control MN CDM740 A 24 Notes...
Страница 150: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...