C
OMREX
C
ORPORATION
24
STAC Product Manual
25
Auto Attendant
is globally disabled (no calls are answered) by setting
Mainframe
DIP Switch 13
to the
ON/UP
position. In the normal
(OFF/
DOWN)
position, the
Auto Attendant
configuration is controlled by the
control surface(s) or by STAC IP.
The
Auto Attendant
button on the control surface or STAC IP interface
is global in reach. For example, if
AA
is selected on one control surface, it
is active on all. When this button is inactive, STAC will not automatically
answer incoming calls. When the button is active, incoming calls will be
automatically answered. The number of rings before answering is selected
via the mainframe
DIP Switch 10
(OFF/DOWN
= 2 rings,
ON/UP
= 6 rings).
To select options for outgoing message, enter
AA Configuration Mode
by
lifting the handset and holding down the
Auto Attendant
button on any
control surface for approximately three seconds. The button will flash, and
you will hear voice prompts on the handset instructing you how to record
and enable outgoing messages. Up to six different 60-second outgoing
messages can be recorded and selected for play. The messages will be
stored in non-volatile memory and will be retained in the event of a power
interruption.
If no message is selected, calls will be answered and put directly to
Hold
status. Remember, after exiting this menu you must leave the
AA
button lit
to enable the
Auto Attendant
function. When
AA
is not illuminated, lines
must be answered manually.