Symptom

Possible cause 

What to do

The thermostat 

does not control 

the gas heater 

at all. 

The thermostat has 

not been connected 

to the gas heater 

properly.

Check the connection 

between 

KonvekPRO

 and the 

thermostat, especially that 

you have connected the 

appropriate connection points 

to 

KonvekPRO

.

Check LEDs on the top 

of 

KonvekPRO

 and the 

temperature of the probe that 

protrudes from 

KonvekPRO

.

In normal operation, when the 

gas heater is not heating, the 

probe is lukewarm (approx. 

30 °C) and the orange LED 

alternately is on and goes out.

If this is not the case 

remove the cable leading 

to the thermostat from the 

KonvekPRO

. If the LED is on 

periodically and the probe 

warms up the defect is in the 

connection to the thermostat 

or in the thermostat.

Try to connect the thermostat 

again, making sure that the 

two wires of the cable do not 

touch.

Содержание KonvekPRO

Страница 1: ...COMPUTHERM KonvekPRO Gas convector controller Operating Instructions...

Страница 2: ...at of the gas heater a copper cartridge containing the expanding fluid connected to the thermostat with a capillary tube To establish the control system a two wire room thermostat should be connected...

Страница 3: ...rmostat sends a signal to KonvekPRO to warm up for 1 1 5 minutes the tube thermostat above the value set by the regulating knob of the gas heater and the gas heater stops heating Using KonvekPRO an au...

Страница 4: ...ermostat and as many KonvekPROs as the number of the gas heaters you want to con trol If you want to control your heating system with a wireless room thermostat then you need only 1 wireless room ther...

Страница 5: ...t in the vicinity of KonvekPRO In this case the thermostat can be moved anywhere within the range IMPORTANT WARNING For proper operation of the gas heater controller turn the temperature regulating kn...

Страница 6: ...and maybe a hammer 2 2 Carefully lift out the probe on the back side of your gas heater from its socket The probe is normally located on the back side of the gas heater in rare cases it is beneath the...

Страница 7: ...7 Put the template to the place where you want to install KonvekPRO Then perforate the template in the middle of the circles indicated by the arrows by means of a pencil...

Страница 8: ...mm put the dowels and screws into them so that 3 4 mm of the screws protrudes from the wall 2 5 Insert the probe of the gas heater carefully into the KonvekPRO The probe receiving socket of the Konvek...

Страница 9: ...KonvekPRO then tighten the fastening screws with a small watchmaker s screwdriver reaching through the holes on its top Several KonvekPRO can be combined and connected to a single thermostat but in th...

Страница 10: ...you should also connect a 230 V cable to points N and L of the receiving unit In general it is expedient to locate the thermostat on the wall of a room where you stay regularly or a long period of ti...

Страница 11: ...11 The following figure shows the control system for gas heaters...

Страница 12: ...12 If you want to control several gas heaters with a single thermostat you can choose between the following connection alternatives...

Страница 13: ...13...

Страница 14: ...the appliance The light of the orange color LED on the top of the appliance provides feedback on automatic operation of KonvekPRO Warning If you do not switch on KonvekPRO the gas heater will heat th...

Страница 15: ...15 Cable fastener used to connect thermostat Power connector Calibration slot Thermostat connector Receiving socket for temperature sensor probe...

Страница 16: ...l mode of the controller the gas heater works fully independently from KonvekPRO and the thermostat connected thereto In such case the gas heater works in the traditional way and can be controlled wit...

Страница 17: ...he orange and blue LEDs on the upper side of the device as follows When the slide switch is MAN position on the left side o When the blue LED is on then the controller works in manual mode o When neit...

Страница 18: ...eed for heating according to the settings of the thermostat The controller has already warmed up sufficiently the temperature sensor probe of the gas heater so that that the gas heater does not heat a...

Страница 19: ...eon KonvekPRO indi cates that it works and has started to heat the probe incorporated therein When the LED goes out the probe reached the temperature set on KonvekPRO After a few minutes the LED is on...

Страница 20: ...value set on KonvekPRO is reached the gas heater ignites This probably will happen near the maximum grade If the gas heater fails to ignite then it means KonvekPRO has heated the probe above the tempe...

Страница 21: ...the bottom of KonvekPRO adjust the potentiometer clockwise in very small increments and wait 4 5 minutes after every adjustment so that the system is stabilized to the new temperature Turn the potent...

Страница 22: ...command given by the thermostat but possible operational instability decreases If you want a quicker operation please decrease the switching threshold value calibration according to Section 6 by sett...

Страница 23: ...ou have nothing to do because it is a part of normal operation The thermostat controls the gas heater after more than 15 minutes or controls it unstably The temperature regulating knob of your gas hea...

Страница 24: ...of KonvekPRO and the temperature of the probe that protrudes from KonvekPRO In normal operation when the gas heater is not heating the probe is lukewarm approx 30 C and the orange LED alternately is...

Страница 25: ...case Unknown Turn to the shop where you bought the product or Quantrax Kft for help If you have a digital hand instrument and some technical expertise please check whether the PSU provided by KonvekPR...

Страница 26: ...ently occur while our appliances are be ing used along with the solutions thereto http www quantrax hu gyik The vast majority of the problems encountered can be solved easily by using the hints availa...

Страница 27: ...0 C 40 C DC adapter voltage DC 12 V 500 mA DC adapter connector 2 1 x 5 5 mm power input max 3 W effective 1 5 W diameter of the connectable temperature sensor probe 6 12 mm heating range of the tempe...

Страница 28: ...ards EU EMC 2014 30 EU LVD 2014 35 EU and RoHS 2011 65 EU Manufacturer QUANTRAX Kft H 6726 Szeged F lem le u 34 Telefon 36 62 424 133 Fax 36 62 424 672 E mail iroda quantrax hu Web www quantrax hu www...

Отзывы: