Compaq ProLiant 800 Servers Maintenance and Service Guide
DAAD Diagnostic Messages
Continued
Message
Description
Recommended Action
Drive (bay) X
firmware needs
upgrading
Firmware on this physical drive is below
the latest recommended version.
Run the Options ROMPaq Utility to upgrade the drive
firmware to the latest revision.
Drive (bay) X has
invalid M&P
stamp
Physical drive has invalid monitor and
performance data.
Run the System Configuration Utility to properly initialize
this drive.
Drive X indicates
position Y
Message indicates which physical drive
appears to be scrambled or in a drive
bay other than the one for which it was
originally configured.
Examine the graphical drive representation on DAAD to
determine proper drive locations. Remove drive X and
place it in drive position Y. Rearrange the drives
according to the DAAD instructions.
Drive (bay) X RIS
copy mismatch
The copies of the RIS on this drive do
not match.
This drive may need to be replaced. Check for
other errors.
Drive (bay) X
upload code not
readable
An error occurred while DAAD was
trying to read the upload code
information from this drive.
If there were multiple errors, this drive may need to
be replaced.
Drive (bay) X has
loose cable
The array controller could not
communicate with this drive at power-
up. This drive has not previously failed.
Check all cable connections first. The cables could be
bad, loose, or disconnected. Turn on the system and
attempt to reconnect signal/power cable to the drive. If
this does not work, replace the cable. If that does not
work, the drive may need to be replaced.
Drive (bay) X is a
replacement drive
This drive has been replaced. This
message displays if a drive is replaced
in a fault tolerant logical volume.
If the replacement was intentional, allow the drive
to rebuild.
Drive (bay) X is a
replacement drive
marked OK
This drive has been replaced and
marked OK by the firmware. This may
occur if a drive has an intermittent
failure (for example, if a drive has
previously failed, then when DAAD is
run, the drive starts working again).
Replace the drive.
Drive (bay) X is
failed
The indicated physical drive has failed.
Replace this drive.
Drive (bay) X has
insufficient
capacity for its
configuration
Drive has insufficient capacity to be
used in this logical drive configuration.
Replace this drive with a larger capacity drive.
Drive (bay) X is
undergoing drive
recovery
This drive is being rebuilt from the
corresponding mirror or parity data.
Normal operations should occur.
Continued