3-9
Compaq ProLiant 800 Servers Maintenance and Service Guide
POST Error Messages
Continued
Error Code
Audible Beeps
L=Long S=Short
Probable Source of Problem
Recommended Action
1702-SCSI cable
error detected.
System halted.
None
Incorrect cabling.
1.
For integrated SCSI
Controllers, ensure that the
internal connector has SCSI
termination attached.
2.
For option card SCSI
controllers, ensure that only
one of the
two internal connectors has
termination attached.
1703-SCSI cable
error detected.
Internal SCSI cable
not attached to
system board
connector. System
halted.
None
Incorrect cabling.
Ensure that the integrated SCSI
controller has SCSI termination
attached.
1704-Unsupported
Virtual Mode Disk
Operation. DOS
Driver Required.
System halted.
None
System attempted to perform a
virtual mode disk operation
without virtual mode
memory services.
Use fixed-disk device driver that
supports virtual mode memory services.
1705-Locked SCSI
Bus Detected.
System halted.
None
SCSI bus failure.
Run Diagnostics. Replace failed
assembly as indicated.
1730-Fixed Disk 0
does not support
DMA Mode.
None
Fixed disk drive error.
Run the System Configuration Utility
and correct.
1731-Fixed Disk 1
does not support
DMA Mode.
None
Fixed disk drive error.
Run the System Configuration Utility
and correct.
1740-Fixed Disk 0
failed Set Block
Mode command
None
Fixed disk drive error.
Run the System Configuration Utility
and correct.
1741-Fixed Disk 1
failed Set Block
Mode command
None
Fixed disk drive error.
Run the System Configuration Utility
and correct.
1750-Fixed Disk 0
failed Identify
command
None
Fixed disk drive error.
Run the System Configuration Utility
and correct.
Continued