Compaq ProLiant 800 Servers Maintenance and Service Guide
POST Error Messages
Continued
Error Code
Audible Beeps
L=Long S=Short
Probable Source of Problem
Recommended Action
1769-Slot x Drive
Array - Drive(s)
disabled due to
failure during
expand. Select
F1
to
continue with logical
drives disabled.
Select
F2
to accept
data loss and to re-
enable logical drives.
None
SMART-2 Controller error.
Data has been lost while expanding the
array, therefore the drives have been
temporarily disabled. Press
F2
to accept
the data loss and re-enable the logical
drives. Restore data from backup.
1771-Primary Disk
Port Address
Assignment Conflict
None
Internal and external hard
drive controllers are both
assigned to the primary
address.
Run the System Configuration Utility
and correct.
1772-Secondary
Disk Port Address
Assignment Conflict
None
Address Assignment Conflict.
Internal and external hard
drive controllers are both
assigned to the secondary
address.
Run the System Configuration Utility
and correct.
1773-Primary Fixed
Disk Port
Assignment Conflict
None
Fixed disk drive error.
Run the System Configuration Utility
and correct.
1774-Slot x Drive
Array - Obsolete data
found in Array
Accelerator. Select
F1
to discard
contents of Array
Accelerator. Select
F2
to write contents
of Array Accelerator
to drives.
None
SMART-2 Controller error.
Data found in Array Accelerator is older
than data found on drives. Press
F1
to
discard the older data in the Array
Accelerator and retain the newer data on
the drives.
1776-Drive Array -
SCSI Port
Termination Error
None
External and internal SCSI
drives are both configured to
Port 1.
Reconfigure drives.
1777-Drive Array
External Drive
Subsystem Error
None
Cooling fan failure, internal
temperature alert or open
side panel.
Inspect for cooling fan failure or open
side panel.
Continued