3-8
Diagnostic Tools
POST Error Messages
Continued
Error Code
Audible Beeps
L=Long S=Short
Probable Source of Problem
Recommended Action
703-CMOS reports a
coprocessor that has
not been detected
2S
Coprocessor or configuration
error.
1.
Run the System Configuration
Utility and correct.
2.
Replace the coprocessor.
1151-Com Port 1
Address Assignment
Conflict
2S
Both external and internal serial
ports are assigned to COM1.
Run the System Configuration Utility
and correct.
1152-Com Port 2, 3,
or 4 Address
Assignment Conflict
2S
Both external and internal serial
ports are assigned to COM2,
COM3 or COM4.
Run the System Configuration Utility
and correct.
1600-Server
Manager/R Failure
None
Server Manager/R board failure.
Error code displays after error
message.
Run Diagnostics. Replace failed
assembly as indicated.
1610-Temperature
violation detected.
Waiting for system
to cool
2S
Ambient system temperature
too hot.
Check fan in system environment.
1611-Fan [fan
description] failure
detected
2S
Required fan has failed.
Check fans.
1611- Fan [fan
description] not
present
2S
Fan not present.
Make sure fans are plugged in.
1612-Primary power
supply failure
2S
Primary power supply
has failed.
Replace power supply as soon
as possible.
1613-Low System
Battery
None
Real time clock system battery
is running low on power.
Run Diagnostics. Replace failed
assembly as indicated.
1615- Power Supply
Failure in Bay X
None
A power supply has failed.
Replace or check specified
power supply.
1616- Power Supply
Configuration Error
2L, 2S
Single power supply system is
installed in Bay 2 and not
in Bay 1.
Move power supply from Bay 2
to Bay 1.
1701-SCSI Controller
failure
None
A test on the Fast SCSI-2
Controller failed
Run Diagnostics. Replace failed
assembly as indicated.
Continued