Compaq ProLiant 5500 and 5500R Maintenance and Service Guide
For use with Pentium II and Pentium III Xeon processor-based servers only
Table 3-21
ADU Diagnostic Messages
continued
Message Description
Recommended
Action
Accelerator
status: Excessive
ECC errors
detected in at
least one cache
line. As a result,
at least on cache
line is no longer
in use
At least one line in the cache is no
longer in use due to excessive ECC
errors detected during use of the
memory associated with that cache
line.
Replacement of the cache should be
considered. If cache replacement is not done,
remaining cache lines should continue to
operate properly.
Accelerator
status: Obsolete
data detected
During reset initialization obsolete
data was found in cache. This was
due to drives being moved and
written to by another controller.
Normal operations should continue. The
controller will either write data to drives or
discard data completely.
Accelerator
status: Obsolete
data was
discarded
During reset initialization obsolete
data was found in cache and was
discarded (not written to drives).
Normal operations should continue.
Accelerator
status: Obsolete
data was flushed
(written) to
drives
During reset initialization obsolete
data was found in cache. Obsolete
data was written to the drives, but
newer data may have been
overwritten.
If newer data was overwritten, you may need to
restore newer data; otherwise, normal
operations should continue.
Accelerator
status:
Permanently
disabled
Array accelerator board has been
permanently disabled. It remains
disabled until it is reinitialized using
the Array Configuration Utility (ACU).
Check the Disable Code field. Run Array
Configuration Utility (ACU) to reinitialize the
array accelerator board.
Accelerator
status: Possible
data loss in
cache
Possible data loss detected during
power-up due to all batteries being
below sufficient voltage level and no
presence of identification signatures
on the array accelerator board.
There is no way to determine if dirty or bad data
was in the cache and is now lost.
Accelerator
status:
Temporarily
disabled
Array accelerator board has been
temporarily disabled.
Check the Disable Code field.
Accelerator
status:
Unrecognized
status
A status returned from the array
accelerator board that ADU does not
recognize.
Obtain the latest version of ADU.
Accelerator
status: Valid data
found at reset
Valid data was found in posted write
memory at reinitialization. Data will
be flushed to disk.
Not an error or data loss condition. No action
needs to be taken.
Accelerator
status: Warranty
alert
Catastrophic problem with array
accelerator board. Refer to other
messages on Diagnostics screen for
exact meaning of this message.
Replace the array accelerator board.
continued