3-12
Compaq ProLiant 5500 and 5500R Maintenance and Service Guide
For use with Pentium II and Pentium III Xeon processor-based servers only
Table 3-2
POST Error Messages
continued
Error Code
Audible Beeps
L=Long S=Short
Probable Source of Problem
Recommended Action
1618-PCI slots
powered down.
Check PCI hot plug
enabler connectors.
None
PCI hot plug enabler is missing or
failed.
Check and replace missing or
failed assembly.
1620-Locked SCSI
Bus Detected. Verify
SCSI bus cabling.
System halted.
None
SCSI bus failure.
Run Diagnostics. Replace failed
assembly as indicated.
1621-Current SCSI
bus cable
configuration is not
recommended
None
Improper SCSI bus cabling.
Check documentation for proper
SCSI bus cabling.
1703-SCSI cable
error detected.
Internal SCSI cable
not attached to
system board
connector. System
halted.
None
Incorrect cabling.
Ensure that the integrated SCSI
controller has SCSI termination
attached.
1720-Slot x Drive
Array – SMART Drive
Detects Imminent
Failure SCSI: Port y:
SCSI ID x
None
Pre-failure condition.
Indicated drive has reported a
SMART predictive-failure
condition and may fail at some
time in the future. If drive is part
of a non-fault-tolerant
configuration, back up all data
before replacing drive and
restore all data afterwards. If
drive is part of a fault-tolerant
configuration,
do not
replace
drive unless all other drives in
array are on-line. Press
F1
to
resume.
1724-Slot x Drive
Array – Physical
Drive Position
Change(s) Detected –
Logical drive
configuration has
automatically been
updated
None
Drive change.
Indicates that logical drive
configuration has been updated
automatically following physical
drive position changes. Press
F1
to resume.