3-26
Compaq ProLiant 5500 and 5500R Maintenance and Service Guide
For use with Pentium II and Pentium III Xeon processor-based servers only
600 – 699, Diskette Drive Test Error Codes
The 600 series of Diagnostic error codes identifies failures with diskette, diskette drive, or
system board functions.
Table 3-8
Diskette Drive Test Error Codes
Error Code
Description
Recommended Action
600-xx
Diskette ID drive types test failed.
601-xx
Diskette format failed.
602-xx
Diskette read test failed.
603-xx
Diskette write/read/compute test
failed.
604-xx
Diskette random seek test failed.
605-xx
Diskette ID media failed.
606-xx
Diskette speed test failed.
607-xx
Diskette wrap test failed.
608-xx
Diskette write protect test failed.
609-xx
Diskette reset controller test
failed.
610-xx
Diskette change line test failed.
694-xx
Pin 34 is not cut on 360 KB
diskette drive.
697-xx Diskette
type
error.
698-xx
Diskette drive speed not within
limits.
1. Replace the diskette and retest.
2. Check and/or replace the diskette power and
signal cables and retest.
3. Replace the diskette drive and retest.
4. Replace the system board and retest.
699-xx
Diskette drive/media ID error.
1. Replace the media and retest.
2. Run the Configuration utility and retest.
Содержание 5500R - ProLiant - 256 MB RAM
Страница 6: ......