Diagnostic Tools
3-9
For use with Pentium II and Pentium III Xeon processor-based servers only
Table 3-2
POST Error Messages
continued
Error Code
Audible Beeps
L=Long S=Short
Probable Source of Problem
Recommended Action
175-
Configuration/Slot
Mismatch Device
Found
None
EISA or PCI board added,
configuration not updated.
Run the System Configuration
Utility and correct.
177-Configuration
Not Complete
None Incomplete
System
Configuration.
Run the System Configuration
Utility and correct.
178-Processor
Configuration Invalid
None
Processor type or step does not
match configuration memory.
Run the System Configuration
Utility and correct.
180-Log Reinitialized
None
N/A
N/A
201-Memory Error
None
RAM failure.
Run Diagnostics. Replace failed
assembly as indicated.
203-Memory
Address Error
None
RAM failure.
Run Diagnostics. Replace failed
assembly as indicated.
207-Invalid Memory
Configuration -
Check DIMM [SIMM]
Installation
None
Memory module installed
incorrectly.
Verify placement of memory
modules.
208-Invalid Memory
Speed - Check DIMM
[SIMM] Installation
1L, 1S
The speed of the memory is too
slow, where: xx00 = expansion
board SIMMs are too slow, or
00yy = system board SIMMs are
too slow. xx and yy have
corresponding bit set.
The speed of the memory
modules must be 60 ns. Verify
the speed of the memory
modules installed and replace.
209-Memory
Detection Failure.
Check Memory
Installation
1L, 1S
Unable to size memory.
Check DIMM installation. If error
persists, replace DIMM.
211-Cache Switch
Set Incorrectly
None
Switch not set properly during
installation or upgrade.
Verify switch settings.
212-System
Processor
Failed/Mapped out
1S
Processor in slot x failed.
Run Diagnostics and replace
failed processor.
214-DC-DC
Converter Failed
None
PowerSafe Module (DC-DC
Converter) failed.
Run Diagnostics. Replace failed
assembly as indicated.
214-Processor PPM
Failed Module X
None
Indicated PPM (DC-DC Converter)
failed.
Replace failed assembly as
indicated.
215-Processor Power
Module has lost
Redundancy in
Socket x
None
PPM (DC-DC Converter) has lost
redundancy.
Run Diagnostics. Replace failed
assembly as indicated.
215-Nonfunctioning
Voltage Regulator
Module for
Processors
None
PPM (DC-DC Converter) has
failed or lost redundancy.
Run Diagnostics. Replace failed
assembly as indicated.
continued