3-56
Compaq ProLiant 5500 and 5500R Maintenance and Service Guide
For use with Pentium II and Pentium III Xeon processor-based servers only
The following ASR-2 flow chart shows you the sequence of events after a hardware or software
error occurs:
Hardware/Software error occurs
|
Error records in the Critical Error Log,
or the Integrated Management Log,
depending on the server
configuration.
|
Operating System halts normal
operation
|
ASR Timer expires
|
Server is reset
|
If a modem is installed and paging
is enabled, the Server Failure
Notification pager alert is sent to
the Server Administrator.
|
Unattended server boots the
Operating System
---Or---
Server boots the Compaq Utilities
on the system partition on the
hard drive
|
If the server continues experiencing
hardware/software errors and the
number of ASR cycles exceed the
specified number of recovery
attempts, the server logs an error to
the Server Health Log or the
Integrated Management Log and
boots the Compaq Utilities from the
system partition on the hard drive.
If a modem is installed, ASR puts
the modem on auto answer so that
the Server Administrator can dial in
(using third party terminal emulator
software) to remotely run the
Compaq Utilities to identify the
source of the fault.
|
Or
|
Local Server Administrator runs
Compaq Utilities from server
console to identify the source
of the fault
Figure 3-1. ASR-2 flow chart
Содержание 5500R - ProLiant - 256 MB RAM