Part Number: EK-BCP24-IA / 161355-001 File Name: F-CH5 ERROR MESSAGES.DOC Last Saved On: 9/30/99 10:29 AM
Table 5-3
Diagnostic Error Messages
continued
Message
Description
Probable Cause
Action
CONFIG VERSION
The switch has encountered an
unrecognized version of the
switch configuration.
OS error
The system resorts to
default configuration
settings
FABRIC,
SEGMENTED,
LOG_WARNING
The fabric is segmented.
■
Fabric
parameters
or switches
not
compatible
■
Conflict
zones
Reconfigure the fabric
or zones
FABRIC,
NO_ALIASID,
LOG_WARNING
There is no free multicast alias.
Too many
multicast groups
in use
Remove some of the
groups
FABRIC, BADILS,
LOG_WARNING
There is a bad ISL-ELS size.
The ISL-ELS
payload is
wrong.
Contact customer
support
FLASH,
BAD_MIRROR,
LOG_WARNING
The system’s flash memory has
encountered an error.
OS error
The system attempts
to recover from its
mirrored backup;
contact customer
support
RPC, SVC_EXIT
An RPC service daemon has
terminated prematurely or
unexpectedly.
OS error
Contact customer
support
RPC, SVC_REG
An RPC service daemon could
not establish service for a
particular protocol handler.
OS error
Contact customer
support
TEMP, 1_FAILED,
LOG_WARNING
The switch overheated.
Fan Failure
Contact customer
support
TEMP, 2_FAILED,
LOG_ERROR
The switch overheated.
Fan Failure
Contact customer
support
TEMP, 3_FAILED,
LOG_CRITICAL
The switch overheated.
Fan Failure
Contact customer
support
TEMP, 4_FAILED,
LOG_CRITICAL
The switch overheated.
Fan Failure
Contact customer
support
continued