![Compaq Storageworks SAN Switch 8 Скачать руководство пользователя страница 66](http://html1.mh-extra.com/html/compaq-storageworks/san-switch-8/san-switch-8_installation-and-hardware-manual_2646671066.webp)
Error Messages
5-11
Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq StorageWorks SAN Switch 8 Installation and Hardware Guide Comments:
Part Number: EK-BCP24-IA / 161355-001 File Name: F-CH5 ERROR MESSAGES.DOC Last Saved On: 9/30/99 10:29 AM
Table 5-3
Diagnostic Error Messages
continued
Message
Description
Probable Cause
Action
DIAG-INTNIL
Err#2031
[cmiTest]
An ASIC failed to receive a
CMI error (interrupt).
ASIC failure
Replace motherboard
assembly
DIAG-INTNOTCLR
Err#102C
[centralMemoryTest]
The interrupt bit could not be
cleared.
ASIC failure
Replace motherboard
assembly
DIAG-LCMEM
Err#1027
[centralMemoryTest,
cmemRetentionTest]
Data read from the Central
Memory location did not match
data previously written into the
same location
ASIC failure
Replace motherboard
assembly
DIAG-LCMEMTX
Err#1F27, 1028
[centralMemoryTest]
A Central Memory transmit path
failed: ASIC 1 failed to read
ASIC 2 through the transmit path.
Motherboard
failure
Replace motherboard
assembly
DIAG-LCMRS
Err#1F25, 1025
[centralMemoryTest,
cmemRetentionTest]
The Central Memory read short:
M bytes were requested but less
than M bytes were received.
ASIC failure
Replace motherboard
assembly
DIAG-LCMTO
Err#1F26, 1026
[centralMemoryTest,
cmemRetentionTest]
The Central Memory timed out:
the data transfer initiated did not
complete within the timeout
period.
ASIC failure
Replace motherboard
assembly
DIAG-MEMNULL
Err#0112
[ramTest]
The test failed to malloc.
Motherboard
failure
Replace motherboard
assembly
DIAG-MEMSZ
Err#0111
[ramTest]
The memory size to be tested is
less than or equal to zero.
Motherboard
failure
Replace motherboard
assembly
continued