4-12
Compaq StorageWorks SAN Switch 8 Installation and Hardware Guide
Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq StorageWorks SAN Switch 8 Installation and Hardware Guide Comments:
Part Number: EK-BCP24-IA / 161355-001 File Name: E-CH4 DIAGNOSTICS.DOC Last Saved On: 9/30/99 10:27 AM
An example mode of operation would be to disable the switch, set the GBIC
mode to 1, and execute the Spin Silk test to limit testing to:
■
Ports with GBIC modules installed
■
Ports that are properly cable loopbacked
IMPORTANT:
This test cannot be executed on an operational switch. Before issuing the
spinSilk command, disable the switch using the switchDisable command.
NOTE:
When running the Spin Silk test, you must set the operating mode value to 0 or 1.
Using operating mode 0 when running the Spin Silk test is recommended.
The command syntax is
spinSilk nMillions
where
nMillions
is the number of frames for the test to execute expressed in
millions of frames. If you do not include the
nMillions
parameter, the Spin Silk
test runs until you press Enter.