Diagnostics
4-7
Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq StorageWorks SAN Switch 8 Installation and Hardware Guide Comments:
Part Number: EK-BCP24-IA / 161355-001 File Name: E-CH4 DIAGNOSTICS.DOC Last Saved On: 9/30/99 10:27 AM
Table 4-3
portLoopbackTest Command Field Descriptions
Field
Description
Diagnostics Status
The title header displays the time diagShow was executed.
port#
The port number.
diags
Port’s current diagnostic status. Possible values include OK or
BAD.
state
Port’s current state. Possible values include UP (active) or
DN (inactive).
lm0-7 (8-port)
lm0-15 (16-port)
The frame counts of active ports. The display shows the
number of frames transmitted and received and low level
interface counts (LLI_errs).
Central Memory Status
Central memory status. Possible values include OK or FAULTY.
Total Diag Frames Tx
The total diagnostics frames transmitted (Tx) since boot. This
number usually corresponds to the total frames received (Rx)
but can differ because of failure modes.
Total Diag Frames Rx
The total diagnostics frames received (Rx) since boot. This
number usually corresponds to the total frames transmitted
(Tx) but can differ because of failure modes.
NOTE:
Related error messages are DIAG-INIT, DIAG-PORTDIED, DIAG-XMIT,
DIAG-TIMEOUT, DIAG-ERRSTAT, DIAG-STATS, DIAG-DATA, and DIAG-PORTABSENT.
sramRetentionTest
Figure 4-7 shows the
sramRetentionTest
command, which verifies that data
written into the ASIC memories are retained and that data bits do not decrease
when read after some amount of delay since the write.
IMPORTANT:
This test cannot be executed on an operational switch. Before issuing the
sramRetentionTest command, disable the switch using the switchDisable command.