![Compaq Storageworks SAN Switch 8 Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/compaq-storageworks/san-switch-8/san-switch-8_installation-and-hardware-manual_2646671043.webp)
Diagnostics
4-9
Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq StorageWorks SAN Switch 8 Installation and Hardware Guide Comments:
Part Number: EK-BCP24-IA / 161355-001 File Name: E-CH4 DIAGNOSTICS.DOC Last Saved On: 9/30/99 10:27 AM
switch:admin> crossPortTest
Running Cross Port Test ............
switchName: JR-6011
switchType: 3.1
switchState: Testing
switchRole: Disabled
switchDomain: 1 (unconfirmed)
switchId: fffc01
switchWwn: 10:00:00:60:69:00:60:11
port 0: sw Testing Loopback->1
port 1: sw Testing Loopback->0
port 2: sw Testing Loopback->7
port 3: sw Testing Loopback->6
port 4: sw Testing Loopback->5
port 5: sw Testing Loopback->4
port 6: sw Testing Loopback->3
port 7: sw Testing Loopback->2
Port SNMP
Physical
Flags
-------------------------------
0: Testing In_Sync
PRESENT ACTIVE E_PORT G_PORT U_PORT SEGMENTED CBL_LB LOGIN
1: Testing In_Sync
PRESENT ACTIVE E_PORT G_PORT U_PORT SEGMENTED CBL_LB LOGIN
2: Testing In_Sync
PRESENT ACTIVE E_PORT G_PORT U_PORT SEGMENTED CBL_LB LOGIN
3: Testing In_Sync
PRESENT ACTIVE E_PORT G_PORT U_PORT SEGMENTED CBL_LB LOGIN
4: Testing In_Sync
PRESENT ACTIVE E_PORT G_PORT U_PORT SEGMENTED CBL_LB LOGIN
5: Testing In_Sync
PRESENT ACTIVE E_PORT G_PORT U_PORT SEGMENTED CBL_LB LOGIN
6: Testing In_Sync
PRESENT ACTIVE E_PORT G_PORT U_PORT SEGMENTED CBL_LB LOGIN
7: Testing In_Sync
PRESENT ACTIVE E_PORT G_PORT U_PORT SEGMENTED CBL_LB LOGIN
Figure 4-9. crossPortTest command example
NOTE:
Related error messages are DIAG-INIT, DIAG-PORTDIED, DIAG-XMIT,
DIAG-TIMEOUT, DIAG-ERRSTAT, DIAG-STATS, DIAG-PORTWRONG, DIAG-DATA, and
DIAG-PORTABSENT.