INS_CWGE26FX2TX24MSPOE_REV– 5 Mar 2014 PAGE 83
INSTALLATION AND OPERATION MANUAL
CWGE26FX2TX24MSPOE
TECH SUPPORT: 1.888.678.9427
ACL Control List
Configure an ACE (Access Control Entry) on this page.
An ACE consists of several parameters. These parameters vary according to the frame type that
you select. First select the ingress port for the ACE, and then select the frame type. Different
parameter options are displayed depending on the frame type that you selected.
A frame that hits this ACE matches the configuration that is defined here.
Label
Description
Ingress Port
Select the ingress port for which this ACE applies.
Any: The ACE applies to any port.
Port n: The ACE applies to this port number, where n is the number of the switch port.
Policy n: The ACE applies to this policy number, where n can range from 1 through 8.
Frame Type
Select the frame type for this ACE. These frame types are mutually exclusive.
Any: Any frame can match this ACE.
Ethernet Type: Only Ethernet Type frames can match this ACE. The IEEE 802.3 specifies
the value of Length/Type Field specifications should be greater than or equal to 1536
decimal (equal to 0600 hexadecimal).
ARP: Only ARP frames can match this ACE. Notice the ARP frames won’t match the ACE
with Ethernet type.
IPv4: Only IPv4 frames can match this ACE. Notice the IPv4 frames won’t match the ACE
with Ethernet type.
Action
Specify the action to take with a frame that hits this ACE.
Permit: The frame that hits this ACE is granted permission for the ACE operation.
Deny: The frame that hits this ACE is dropped.
Rate Limiter
Specify the rate limiter in number of base units. The allowed range is 1 to 15. Disabled
indicates that the rate limiter operation is disabled.
Port Copy
Frames that hit the ACE are copied to the port number specified here. The allowed
range is the same as the switch port number range. Disabled indicates that the port
copy operation is disabled.