INS_CWGE24MS_REV–
02/18/13 PAGE 8
INSTALLATION AND OPERATION MANUAL
CWGE24MS
TECH SUPPORT: 1.888.678.9427
»
LED for STA: Green: Indicates that the system ready. The LED is blinking when the system is
upgrading firmware
»
LED for PWR: This LED lights on when the power module is activated.
»
LED for R.M. (Ring master): When the LED lights on, this switch is designated as the ring
master of the Ring topology.
»
LED for Ring: When the LED light on, the C-Ring is activated.
»
LED for DEF: System resets to default configuration.
»
LED for Ping: System is processing “PING” request.
»
LED for RUN: System is operating continuously.
»
LED for RMT: System is accessed remotely.
»
LED for Fault: Indicates unexpected event occurred.
Rear Panel
The rear panel of CWGE24MS is displayed as below:
I
0
CWGE24MS
1
2
3
CWGE24MS Rear Panel
1. Power Switch
2. Power input for AC 100V~240V / 50~60Hz.
3. Power input for DC 36~72V and fault relay output