background image

INSTALLATION AND OPERATION MANUAL 

CWGE24MS

COMMERCIAL GRADE MANAGED ETHERNET SWITCH WITH (8) 

100/1000BASE-FX & (16) GIGABIT COMBO PORTS

v1.4 January 5, 2016

The ComNet CWGE24MS has eight 100/1000Base-FX SFP ports and sixteen Gigabit 
combo ports that allow for TX or FX transmission. All SFP ports utilize ComNet Small 
Form Factor (SFP) pluggable modules for the selection of fiber and connector type and 
distance. The IEEE802.3-compliant unit offers multiple Ethernet redundancy protocols 
(ComRing, C-Ring, and MSTP/RSTP/STP) which protect your applications from network 
interruptions or temporary malfunctions by redirecting transmission within the 
network. The switch provides advanced IP-based management that can limit the 
maximum bandwidth for each connected IP device, allowing the user to adjust 
usage. Application-based QoS can set a higher priority for data streaming. The Device-
Binding function can prevent unauthorized network access, increasing security. The 
unit also provides advanced DOS/DDOS auto prevention. If IP flow becomes too large, 
too quickly, the switch will lock the source IP address for a set period preventing 
unauthorized access. The switch offers centralized and convenient management and 
is also configurable by Web-based Telnet, and Console (CLI) configurations. 

Содержание CWGE24MS

Страница 1: ...ications from network interruptions or temporary malfunctions by redirecting transmission within the network The switch provides advanced IP based management that can limit the maximum bandwidth for e...

Страница 2: ...roduction 4 Software Features 5 Hardware Features 6 Hardware Overview 7 Front Panel 7 Rear Panel 8 Rack mount kit assembly 9 Front Panel LEDs 10 Cables 11 Ethernet Cables 11 10 100 1000BASE T X Pin As...

Страница 3: ...utor This warranty does not cover product modifications or repairs done by persons other than ComNet approved personnel and this warranty does not apply to ComNet products that are misused abused impr...

Страница 4: ...nctions with its fast recovery technology ComNet switches provide advanced and IP based bandwidth management that can limit the maximum bandwidth for each IP device The user can configure IP camera an...

Страница 5: ...trap and Relay Output Web based Telnet and Console CLI configuration Enable disable ports MAC based port security Port based network access control IEEE 802 1x VLAN IEEE 802 1q to segregate and secur...

Страница 6: ...Hardware Features 3 Redundant power inputs Operating Temperature 0 to 50 C Storage Temperature 40 to 85 C Operating Humidity 5 to 95 non condensing Casing IP 30 Aluminum 16 Combo ports with 10 100 100...

Страница 7: ...WGE24MS 1 5 6 7 2 3 8 4 8 CWGE24MS Front Panel 1 Console port DB9 2 10 100 1000Base T X Ethernet port and 100 1000Base X SFP combo port 3 100 1000Base X Fiber port on SFP 4 Reset button Push the butto...

Страница 8: ...ignated as the ring master of the Ring topology LED for Ring When the LED light on the C Ring is activated LED for DEF System resets to default configuration LED for Ping System is processing PING req...

Страница 9: ...STALLATION AND OPERATION MANUAL CWGE24MS TECH SUPPORT 1 888 678 9427 Rack mount kit assembly You can find the rack mount kit and the screws in the packing box Please assemble the rack mount kit on the...

Страница 10: ...PWR Green On DC power module activated Ping Green Blinking System is processing PING request RMT Green Blinking System is accessed remotely Ring Green On Ring enabled Slowly blinking Ring has only On...

Страница 11: ...fications Cable Types and Specifications Cable Type Max Length Connector 10BASE T Cat 3 4 5 100 UTP 100m 328ft RJ 45 100BASE TX Cat 5 100 UTP UTP 100m 328ft RJ 45 1000BASE TX Cat 5 Cat 5e 100 UTP UTP...

Страница 12: ...MS switches support auto MDI MDI X operation You can use a straight through cable to connect PC to switch The following table below shows the 10 100BASE T X MDI and MDI X port pin outs 10 100 Base T M...

Страница 13: ...5 BI_DC BI_DD 6 BI_DB BI_DA 7 BI_DD BI_DC 8 BI_DD BI_DC Note and signs represent the polarity of the wires that make up each wire pair SFP The Switch has fiber optic ports that utilize SFP connectors...

Страница 14: ...14 INSTALLATION AND OPERATION MANUAL CWGE24MS TECH SUPPORT 1 888 678 9427 Console Cable Each CWGE24MS switch can be managed by its console port You can connect them to PC via an RS 232 cable with DB...

Страница 15: ...ata Transmitted from DCE Device 3 Transmitted Data Transmitted from DTE Device Received Data Received by DCE Device 4 DTE Ready Transmitted from DTE Device DTE Ready Received by DCE Device 5 Signal Gr...

Страница 16: ...t features and allows you to manage the switch from anywhere on the network through a standard web browser such as Microsoft Internet Explorer The Web Based Management function supports Internet Explo...

Страница 17: ...427 System Login 1 Launch your Web Browser 2 Type http and the IP address of the switch Press Enter 3 The login screen appears 4 Enter username and password The default username and password is admin...

Страница 18: ...13 PAGE 18 INSTALLATION AND OPERATION MANUAL CWGE24MS TECH SUPPORT 1 888 678 9427 Main Interface Main interface Basic Setting System Information The switch system information is provided here System...

Страница 19: ...tents are the ASCII characters from 32 to 126 System Contact The textual identification of the contact person for this managed node together with information on how to contact this person The allowed...

Страница 20: ...o not need to assign the IP address The network DHCP server will assign the IP address for the switch and it will be display in this column The default IP is 192 168 10 1 IP Mask Assign the subnet mas...

Страница 21: ...ration Disabled Disable HTTPS mode operation Save Select to save changes Reset Select to undo any changes made locally and revert to previously saved values SSH Label Description Mode Indicates the SS...

Страница 22: ...current LLDP port settings Label Description TX Interval The switch periodically transmits LLDP frames to its neighbors for keeping the network discovery information up to date The interval between ea...

Страница 23: ...neighbor unit Port Description Port Description is the port description advertised by the neighbor unit System Capabilities System Capabilities describes the neighbor unit s capabilities The possible...

Страница 24: ...bel Description Neighbor entries were last changed at Shows the time for when the last entry was last deleted or added It is also shows the time elapsed since last change was detected Total Neighbors...

Страница 25: ...the table Entries are removed from the table when a given port links down an LLDP shutdown frame is received or when the entry ages out TLVs Discarded Each LLDP frame can contain multiple pieces of i...

Страница 26: ...ou can save view or load the switch configuration The configuration file is in XML format with a hierarchy of tags Firmware Update This page facilitates an update of the firmware controlling the switc...

Страница 27: ...ation and display in here DHCP Client List You can assign the specific IP address that is in the assigned dynamic IP range to the specific port When the device is connecting to the port and asks for d...

Страница 28: ...he Current Rx column indicates whether pause frames on the port are obeyed and the Current TX column indicates whether pause frames on the port are transmitted The Rx and TX settings are determined by...

Страница 29: ...nit is kbps and it is restricted to 1 1000 when the Policer Unit is Mbps Policer Unit Configure the unit of measure for the port policer rate as kbps or Mbps The default value is kbps Shaper Enabled E...

Страница 30: ...nabled Destination MAC Address The Destination MAC Address can be used to calculate the destination port for the frame Check to enable the use of the Destination MAC Address or uncheck to disable By d...

Страница 31: ...Normal indicates there is no aggregation Only one group ID is valid per port Port Members Each switch port is listed for each group ID Select a radio button to include a port in an aggregation or clea...

Страница 32: ...the aggregation By default no ports belong to any aggregation group Only full duplex ports can join an aggregation and ports must be in the same speed in each group Key The Key value incurred by the...

Страница 33: ...own as isid aggr id and for GLAGs as aggr id Partner System ID The system ID MAC address of the aggregation partner Partner Key The Key that the partner has assigned to this aggregation ID Last Change...

Страница 34: ...is down Backup means that the port could not join the aggregation group but will join if other port leaves Meanwhile its LACP status is disabled Key The key assigned to this port Only ports with the s...

Страница 35: ...t number LACP Transmitted Shows how many LACP frames have been sent from each port LACP Received Shows how many LACP frames have been received at each port Discarded Shows how many unknown or illegal...

Страница 36: ...ng is the most powerful Ring in its class The recovery time of C Ring is less than 20 ms for Gigabit Ethernet switches It can reduce unexpected damage caused by network topology change C Ring Supports...

Страница 37: ...two smaller rings to avoid effecting all switches when network topology change It is a good application for connecting two Rings Coupling Port Link to Coupling Port of the switch in another ring Coupl...

Страница 38: ...re The switch supports the function and interface for setting the switch as the ring master or not The ring master can negotiate and place command to other switches in the X Ring group If there are 2...

Страница 39: ...her vendor s managed switch ComRing interface Label Description Enable Enable the COM Ring function Vendor Select the vendor whose ring you want to join 1st Ring Port Select the port that connects to...

Страница 40: ...age of the information transmitted by the Bridge when it is the Root Bridge Valid values are in the range 6 to 40 seconds and MaxAge must be FwdDelay 1 2 Maximum Hop Count This defines the initial va...

Страница 41: ...re spanning trees for MSTI s Intra region The name is at most 32 characters Configuration Revision The revision of the MSTI configuration named above This must be an integer between 0 and 65535 MSTI T...

Страница 42: ...them as well Label Description MSTI The bridge instance The CIST is the default instance which is always active Priority Controls the bridge priority Lower numerical values have better priority The b...

Страница 43: ...AL CWGE24MS TECH SUPPORT 1 888 678 9427 CIST Ports This page allows the user to inspect the current STP CIST port configurations and possibly change them as well This page contains settings for physic...

Страница 44: ...ot Restricted Role If enabled causes the port not to be selected as Root Port for the CIST or any MSTI even if it has the best spanning tree priority vector Such a port will be selected as an Alternat...

Страница 45: ...d possibly change them as well A MSTI port is a virtual port which is instantiated separately for each active CIST physical port for each MSTI instance configured and applicable for the port The MSTI...

Страница 46: ...ng the 802 1D recommended values Using the Specific setting a user defined value can be entered The path cost is used when establishing the active topology of the network Lower path cost ports are cho...

Страница 47: ...e Bridge ID of this Bridge instance Root ID The Bridge ID of the currently elected root bridge Root Port The switch port currently assigned the root port role Root Cost Root Path Cost For the Root Bri...

Страница 48: ...P port CIST Role The current STP port role of the CIST port The port role can be one of the following values AlternatePort BackupPort RootPort DesignatedPort State The current STP port state of the CI...

Страница 49: ...received transmitted on the port STP The number of legacy STP Configuration BPDUs received transmitted on the port TCN The number of legacy Topology Change Notification BPDUs received transmitted on...

Страница 50: ...e VLAN ID The VLAN ID for the entry MAC Address The MAC address for the entry Port Members Checkmarks indicate which ports are members of the entry Check or uncheck as needed to modify the entry Add n...

Страница 51: ...OPERATION MANUAL CWGE24MS TECH SUPPORT 1 888 678 9427 Example Portbased VLAN Setting For ingress port 1 VLAN Membership Configuration setting port 1 VID 50 2 VLAN Port 1 Configurations Disable VLAN Aw...

Страница 52: ...ERATION MANUAL CWGE24MS TECH SUPPORT 1 888 678 9427 For egress port 1 VLAN Membership Configuration setting port 2 VID 50 2 VLAN Port 2 Configuration don t care VLAN Aware 3 VLAN Port 2 Configuration...

Страница 53: ...AND OPERATION MANUAL CWGE24MS TECH SUPPORT 1 888 678 9427 802 1Q Access port Setting For ingress port 1 VLAN Membership Configuration setting port VID 50 2 VLAN Port Configurations Enable VLAN Aware...

Страница 54: ...ATION MANUAL CWGE24MS TECH SUPPORT 1 888 678 9427 For egress port 1 VLAN Membership Configuration setting port VID 50 2 VLAN Port Configurations Disable VLAN Aware 3 VLAN Port Configuration Mode speci...

Страница 55: ...CWGE24MS CWGE24MS PC B PC A P1 P2 P6 P5 For ingress port 1 VLAN Membership Configuration setting port VID 11 22 33 2 VLAN Port Configurations Enable VLAN Aware 3 VLAN Port Configuration Mode specific...

Страница 56: ...ECH SUPPORT 1 888 678 9427 For egress port 1 VLAN Membership Configuration setting port VID 11 22 33 2 VLAN Port Configurations Enable VLAN Aware 3 VLAN Port Configuration Mode none Egress port can re...

Страница 57: ...ATION AND OPERATION MANUAL CWGE24MS TECH SUPPORT 1 888 678 9427 QinQ VLAN Setting CWGE24MS PC PC P3 P1 P2 Tag 50 tag 77 packet ingress Port 1 egress Port 2 For Ingress port Port 1 1 VLAN Membership Co...

Страница 58: ...WGE24MS_REV 02 18 13 PAGE 58 INSTALLATION AND OPERATION MANUAL CWGE24MS TECH SUPPORT 1 888 678 9427 2 VLAN Port Configuration Disable Port 1 VLAN Aware 3 VLAN Port Configuration Port 1 Mode specific I...

Страница 59: ...ION MANUAL CWGE24MS TECH SUPPORT 1 888 678 9427 For egress port Port 2 1 VLAN Membership Configuration setting port VID 50 2 VLAN Port Configuration Enable Port 2 and 3 VLAN Aware 3 VLAN Port Configur...

Страница 60: ...entry It will be deleted during the next save Private VLAN ID Indicates the ID of this particular private VLAN MAC Address The MAC address for the entry Port Members A row of check boxes for each port...

Страница 61: ...TECH SUPPORT 1 888 678 9427 Label Description Port Members A check box is provided for each port of a private VLAN When checked port isolation is enabled for that port When unchecked port isolation i...

Страница 62: ...content is the ASCII characters from 33 to 126 The field only suits to SNMPv1 and SNMPv2c SNMPv3 is using USM for authentication and privacy and the community string will associated with SNMPv3 commu...

Страница 63: ...is switch IPv6 address is in 128 bit records represented as eight fields of up to four hexadecimal digits with a colon separates each field For example fe80 215 c5ff fe03 4dc7 The symbol is a special...

Страница 64: ...s 0 to 255 SNMP Communities Configure SNMPv3 community s table on this page The entry index key is Community Label Description Delete Check to delete the entry It will be deleted during the next save...

Страница 65: ...user name that this entry should belong to The allowed string length is 1 to 32 and the allowed content is the ASCII characters from 33 to 126 Security Level Indicates the security model that this en...

Страница 66: ...gure SNMPv3 groups table on this page The entry index keys are Security Model and Security Name Label Description Delete Check to delete the entry It will be deleted during the next save Security Mode...

Страница 67: ...d content is the ASCII characters from 33 to 126 View Type Indicates the view type that this entry should belong to Possible view types are included An optional flag to indicate that this view subtree...

Страница 68: ...els are any Accepted any security model v1 v2c usm v1 Reserved for SNMPv1 v2c Reserved for SNMPv2c usm User based Security Model USM Security Level Indicates the security model that this entry should...

Страница 69: ...Priority Frames not matching any of the QCEs are classified to the default QoS class for the port Port QoS Configuration Label Description Port A check box is provided for each port of a private VLAN...

Страница 70: ...ing QCE types are supported Ethernet Type The Ethernet Type field If frame is tagged this is the Ethernet Type that follows the tag header VLAN ID VLAN ID Only applicable if the frame is VLAN tagged T...

Страница 71: ...r second The configuration indicates the permitted packet rate for unicast multicast or broadcast traffic across the switch Note Frames which are sent to the CPU of the switch are always limited to ap...

Страница 72: ...s according to different QCL policies Set up Typical Network Application Rules Set up the specific QCL for different typical network application quality control Set up ToS Precedence Mapping Set up th...

Страница 73: ...r VLAN IGMP Snooping IGMP Querier Enable the IGMP Querier in the VLAN The Querier will send out if no Querier received in 255 seconds after IGMP Querier Enabled Each Querier s interval is 125 second a...

Страница 74: ...ry Querier Status Show the Querier status is ACTIVE or IDLE Querier Receive The number of Transmitted Querier V1 Reports Receive The number of Received V1 Reports V2 Reports Receive The number of Rece...

Страница 75: ...to this port The allowed values are Disabled or the values 1 through 15 The default value is Disabled Port Copy Select which port frames are copied to The allowed values are Disabled or a specific por...

Страница 76: ...the Reauthentication Period Reauthentication for 802 1X enabled ports can be used to detect if a new device is plugged into a switch port For MAC based ports reauthentication is only useful if the RA...

Страница 77: ...es to ports running MAC based authentication only If the RADIUS server denies a client access or a RADIUS server request times out according to the timeout specified on the Authentication configuratio...

Страница 78: ...from the list box allows the port to consume up to 48 client state machines Choosing the value Specific from the list box opens up for entering a specific number of maximum clients on the port 1 to 4...

Страница 79: ...cation Server by checking this box IP Address Enable fallback to local authentication by checking this box If none of the configured authentication servers are alive the local user database is used fo...

Страница 80: ...t is happening the Fault LED in switch panel will light up and the relay will signal at the same time The following table describes the labels in this screen Label Description Power Failure Mark the b...

Страница 81: ...3164 The BSD SYSLOG Protocol The following table describes the labels in this screen Label Description IP Address The remote SYSLOG Server IP address Save Select to save the configurations Reset Selec...

Страница 82: ...is in control of the mode and the user cannot change it An example of such a module is the MAC Based Authentication under 802 1X Each port can perform learning based upon the following settings Label...

Страница 83: ...table is sorted first by VLAN ID and then by MAC address Label Description Delete Check to delete the entry It will be deleted during the next save VLAN ID The VLAN ID for the entry MAC Address The MA...

Страница 84: ...ts that have either source RX or destination TX Mirroring enabled are mirrored to this port Disabled disables Mirroring Label Description Port The logical port for the settings contained in the same r...

Страница 85: ...of the system log All All levels Time The time of the system log entry Message The MAC Address of this switch Auto refresh Check this box to enable an automatic refresh of the page at regular interval...

Страница 86: ...mitted packets per port Bytes The number of received and transmitted bytes per port Errors The number of frames received in error and the number of incomplete transmissions per port Drops The number o...

Страница 87: ...e provides detailed traffic statistics for a specific switch port Use the port select box to select which switch port details to display The displayed counters are the totals for receive and transmit...

Страница 88: ...s port that have an opcode indicating a PAUSE operation Rx Drops The number of frames dropped due to lack of receive buffers or egress congestion Rx CRC Alignment The number of frames received with CR...

Страница 89: ...responses to all packets are received or until a timeout occurs PING6 server 10 10 132 20 64 bytes from 10 10 132 20 icmp_seq 0 time 0ms 64 bytes from 10 10 132 20 icmp_seq 1 time 0ms 64 bytes from 10...

Страница 90: ...LATION AND OPERATION MANUAL CWGE24MS TECH SUPPORT 1 888 678 9427 SFP Monitor The DDM function can pass SFP module which supports DDM function measure the temperature of the apparatus And manage and se...

Страница 91: ...s automatically and you can view the cable diagnostics results in the cable status table Note that VeriPHY is only accurate for cables of length 7 140 meters 10 and 100 Mbps ports will be linked down...

Страница 92: ...is retained Label Description Yes Select to reset the configuration to Factory Defaults No Select to return to the Port State page without resetting the configuration System Reboot You can reset the...

Страница 93: ...sole or telnet to management switch by CLI CLI Management by RS 232 Serial Console 115200 8 none 1 none Before Configuring by RS 232 serial console use an DB 9 M to DB 9 F cable to connect the switche...

Страница 94: ...ALLATION AND OPERATION MANUAL CWGE24MS TECH SUPPORT 1 888 678 9427 Step 3 Select to use COM port number Step 4 The COM port properties setting 115200 for baud rate 8 for Data bits None for Parity 1 fo...

Страница 95: ...ALLATION AND OPERATION MANUAL CWGE24MS TECH SUPPORT 1 888 678 9427 Step 5 The Console login screen will appear Use the keyboard to enter the Username and Password these are the same as the credentials...

Страница 96: ...192 168 10 1 Subnet Mask 255 255 255 0 Default Gateway 192 168 10 254 User Name admin Password admin Follow the steps below to access the console via Telnet Step 1 Telnet to the IP address of the swit...

Страница 97: ...TECH SUPPORT 1 888 678 9427 Commander Groups System System Configuration all port_list Reboot Restore Default keep_ip Contact contact Name name Location location Description description Password passw...

Страница 98: ...server_index enable disable ip_addr_string secret server_port ACCT_RADIUS server_index enable disable ip_addr_string secret server_port Client console telnet ssh web none local radius enable disable...

Страница 99: ...RT 1 888 678 9427 Aggr Aggr Configuration Add port_list aggr_id Delete aggr_id Lookup aggr_id Mode smac dmac ip port enable disable LACP LACP Configuration port_list Mode port_list enable disable Key...

Страница 100: ...rt_list Msti Priority msti priority Msti Map msti clear Msti Add msti vid Port Configuration port_list Port Mode port_list enable disable Port Edge port_list enable disable Port AutoEdge port_list ena...

Страница 101: ...l radius Clients port_list all client_cnt Agetime age_time Holdtime hold_time IGMP IGMP Configuration port_list Mode enable disable State vid enable disable Querier vid enable disable Fastleave port_l...

Страница 102: ...r vid Agetime age_time Learning port_list auto disable secure Dump mac_max mac_addr vid Statistics port_list Flush VLAN VLAN Configuration port_list Aware port_list enable disable PVID port_list vid n...

Страница 103: ...l_id qce_id qce_id_next etype etype vid vid port udp_tcp_port dscp dscp tos tos_list tag_prio tag_prio_list class QCL Delete qcl_id qce_id QCL Lookup qcl_id qce_id Mode port_list strict weighted Weigh...

Страница 104: ...t port policy policy vid tag_prio dmac_type etype etype smac dmac arp sip dip smac arp_opcode arp_flags ip sip dip protocol ip_flags icmp sip dip icmp_type icmp_code ip_flags udp sip dip sport dport i...

Страница 105: ...e MD5 SHA auth_password DES priv_password User Delete index User Changekey engineid user_name auth_password priv_ password User Lookup index Group Add security_model security_name group_name Group Del...

Страница 106: ...Tagging IEEE 802 1D for STP Spanning Tree Protocol IEEE 802 1w for RSTP Rapid Spanning Tree Protocol IEEE 802 1s for MSTP Multiple Spanning Tree Protocol IEEE 802 1x for Authentication IEEE 802 1AB f...

Страница 107: ...Green Indicate Power 1 input Power 2 Indicator PW2 Green Indicate Power 2 input Power 3 Indicator PW3 Green Indicate Power 3 input System Ready Indicator STA Green Indicates that the system ready The...

Страница 108: ...Overload current protection Present Physical Characteristic Enclosure 19 inches rack mountable Dimension W x D x H 431 W x 342 D x 44 H mm Weight g 4 5 Kg Environmental Storage Temperature 40 to 85 C...

Страница 109: ...CH SUPPORT 1 888 678 9427 INFO COMNET NET 8 TURNBERRY PARK ROAD GILDERSOME MORLEY LEEDS UK LS27 7LE T 44 0 113 307 6400 F 44 0 113 253 7462 INFO EUROPE COMNET NET MECHANICAL INSTALLATION INSTRUCTIONS...