Install the Subracks and PSU in an Equipment Rack
4
Connect the e-POI communications and power cables from the WCS to the e-POI subrack (if used).
The -48Vdc DC power entry connector is hot plug/unplug tolerant and has reverse polarity protection.
Table 11.
-48Vdc WCS DC Power Supply Requirements
DC Power Supply Requirements
Input Voltage Range
-40 Vdc to -60 Vdc
Current -48Vdc WCS-4
20A maximum
Current -48Vdc WCS-2
15A maximum
-48Vdc WCS-4 Max Load
691 Watts
-48Vdc WCS-2 Max Load
418 Watts
-48Vdc WCS-2 Max Load
(TEN Configuration)
115 Watts