Data is programmed as follows: place the TPU-AN or TS-AN-HF into programming mode. Operate the key
associated with the data category to be programmed and the display shows the code for that data
category. Enter data by using the dial on the TPU-AN or TS-AN-HF. Dial
to send the write command
and dial
to terminate a data category.
When the data programming is completed press the “CHECK” key followed by the DSS 16
key.
The display will show “P” if the data has been accepted, or an error code if the data has not been
accepted (refer to Table
If you go out of programming mode without pressing “CHECK” and DSS
16 keys or without the display showing “P”, when these keys are pressed, then all data entered since the
last time data was accepted, will be lost.
The data categories affected must be reprogrammed.
The system will reset, dropping ail calls, when programming mode is left if any data has been
changed.
-ERROR CODE
DESCRIPTION
P
Programmed data is correct.
C - - - -
WR switch on CPB-AN is set to
position.
- - - - 1
Lines have been assigned as PABX, but trunk access code has not been programmed.
- - - - 2
Lines have been assigned as PABX, but PABX pause is set to zero.
- - - - 3
Call forwarding data is in error.
- - - - 4
Manager station is not assigned DND
- - - - 5
Signalling time out is set to zero
- - - - 6
Ring inward timer is set to zero
- - - - 7
Exclusive line assigned to secretary
- - - -
Two exclusive lines assigned to one station.
Table 2.7.1 PROGRAMMING ERROR CODES
2.7.2
Checking Programmed Data
Programming data may be reviewed as follows:
Place the TPU-AN or TS-AN-HF in the programming mode by pressing the programming button. Press the
“CHECK” key followed by the appropriate key related to the data category you wish to check. The display
will show a
in front of the data category code. Dial
to step through the programmed data and
to terminate the data category.
To modify existing data follow the programming procedure for that data category.
2.7.3
Re-initiaiising Programmed Data
Programming data may be reset to initial conditions as follows:
Turn power off and set the WR switch to the
position. Turn power on, wait for ten seconds, then set
the WR switch to the
position.
2.7.4
Facility Programming
Press the programming button on the TPU-AN or TS-AN-HF and proceed to program the facilities as
described in the following sections.
2.7.4.1
Diaiiing Mode (F-l
DSS key F-l is used to assign each line to dial in either decadic or VF mode. To programme, dial the line
number,
l
, then
for decadic or
for VF.
Example: programme line 1 as decadic, line 2 as VF:
PRESS
DIAL
1
1
“2”
DISPLAY
0 6
1
1
1
1
(line 1
2
2
2
0
(line 2
54
AN-61 6
ISSUE