OPTION SELECTION SWITCH
The SW1 switch (Figure
is used to select printout options.
SW I- 1
of Digits in
Number to be Printed
OFF
All digits are printed
ON
The last two digits are not printed.
SW l-2: Duration of Calls to be Printed
OFF
Outgoing calls printed only if their duration is more than 1 minute
ON
All outgoing calls are printed.
SW l-3: Delay Before Call Duration is Timed
OFF
Timer starts 1 second after dialling.
ON
Timer starts 5 seconds after dialling.
-4:Account Code
OFF
An account code must be entered before dialling is allowed.
ON
Account code is optional and may be entered anytime when required.
SW1 -5:lncoming Calls
OFF
Print answered incoming calls only if an account code is entered.
ON
Print all incoming calls.
SW1 -6:Barred Calls
OFF
Print details of barred calls
ON
No printout for barred calls
SW1 -7,B: Not Used Set to ON.
The SW2 switch is not used and should be set to all ON.
CONNECTOR
The jack assembly is connected to the CDRB-AN connector
via a ribbon cable. A printer is then
connected to the jack assembly via an RS-232C cable.
2.5.5
PWLB-AN
The
board is installed into an SLB-AN slot in order to provide an interface for four standard
telephone stations and two outside lines. A daughter board
is attached to
via
connector
The locations of the connector, links and
are shown in figure 2.5.5.
m
Fig. 2.5.5.
CONNECTOR AND LINK LOCATIONS
ON THE
BOARD
52
AN-61 6
ISSUE 1