4K HDBaseT 4x4 Matrix Switcher
4.4
TCP/IP Control
4K HDBaseT 4x4 Matrix Switcher boasts option TCP/IP port for IP control.
Default settings: IP: 192.168.0.178; Subnet Mast: 255.255.255.0; Gateway:
192.168.0.1; Serial Port: 4001.
IP& gateway can be changed as you need, Serial Port cannot be changed.
Connect the Ethernet port of control device and TCP/IP port of 4K HDBaseT 4x4
Matrix Switcher, and set same network segment for the 2 devices, users are able to
control the device via web-based GUI or designed TCP/IP communication software.
4.4.1
Control Modes
4K HDBaseT 4x4 Matrix Switcher can be controlled by PC without Ethernet access
or PC(s) within a LAN.
● Controlled by PC
Connect a computer to the TCP/IP port of the 4K HDBaseT 4x4 Matrix Switcher,
and set its network segment to the same as the 4K HDBaseT 4x4 Matrix Switcher’s
(Default: 192.168.0.178).
● Controlled by PC(s) in LAN
Connect 4K HDBaseT 4x4 Matrix Switcher, a router and several PCs to setup a
LAN (as shown in the following figure). Set the network segment of 4K HDBaseT
4x4 Matrix Switcher to the same as the router’s, then PCs within the LAN are able
to control 4K HDBaseT 4x4 Matrix Switcher.
Comm-tec Srl
29