E. Environmental
Specifications
Operating Temperature & Humidity
Operating range:
+10 to +40
°
C (50 to 104
°
F) ambient, 5-85% R.H. (non-
condensing, no formation of ice), 86-106 kPa.
Temperature, humidity and air pressure operating range
class 3K3 per prEN50178.
Cooling Inlet Air:
+5 to +35
°
C max (41 to 95
°
F)
Inlet Water Cooling Requirements:
6 l/m (1.6 GPM) @ 414 kPa (60 psi) max, +5
°
to max
25
°
C (40
°
F to 77
°
F)
Coolant type:
Water
Storage and Transportation
Storage temperature/humidity/air pressure:
-25 to +70
°
C (class 1k4 per prEN50178), 5 - 95%
humidity (non-condensing, no formation of ice, class 1k3),
70-106 kPa (class 1k4).
Transport temperature/humidity/air pressure:
-25 to +70
°
C, 5 - 95% humidity, 70-106 kPa
(class 2k3).
This equipment has been designed to be compliant with FCC Part 18 emission standards for EMI/RFI
radiation. Radiated emissions shall also not exceed maximum levels permitted by ANSI C95.1-1982 standards
on safety levels with respect to human exposure to RF and electromagnetic fields from 300KHz to 100GHz.
F. Testing
Specifications
Production Acceptance Test: Each unit will be required to "pass" production acceptance testing and a "Final
Test Report" will be generated to document results.
Production Acceptance Testing process shall include as a minimum: Complete Parametric/Functional Tests
covering: line regulation, calibration, linearity, burn-in, over-temp test, open circuit test, MAX power test,
harmonic distortion, AC ripple, and remote interface tests. Data sheet for each generator to be shipped with unit.
G. Packaging & Shipping Specifications
1. Accessories Supplied
•
Final test results
•
Operating manual
2. Shipping
NOTE: If there is a conflict between this document and customer Purchase Order then the latter
supersedes.
NOTE FOR REPAIRS: Unless repairs have accessories included with them and have them listed on
the Return Material Authorization (RMA) Tag, returned materials will not have to fulfill procedural
requirements for accessories.