CDX2000 / 13.56 MHz & 400 kHz Manual
© 2006 Comdel, Inc.
16
2. Lock: The lock setting determines the percent (of FWD) rise of RFL that the tuning algorithm will tolerate
after passing through a null. If the RFL reaches this number the autotune will lock at the null frequency
setting. Lock is adjusted by setting dipswitch positions 3&4. The Lock settings vary as follows:
0
1
1
2
2
3
3
5
3. Band: The band setting determines when the autotune algorithm will attempt to retune based on the rise
in the RFL by percent of FWD. The band is adjusted by setting dip switch positions 5&6 and varies as
follows:
0
.5
1
1
2
2
3
3
4. Scale: The scale setting determines whether the frequency step size is proportional to the SWR or the
square root of the SWR. The scale is set by switch 7. Typically the square root setting will tune faster:
0
SQUARE ROOT
1
LINEAR
5. Start: The start setting determines whether the frequency starts at MIN frequency and tunes up or starts at
MAX frequency and tunes down. The start is adjusted by switch 8:
0
START LOW
1
START HIGH
8
Certification
1.
This unit carries the ETL safety compliance mark to UL standard UL-1012.
2.
This unit is SEMI F47 voltage sag immunity tested.
3.
This unit is designed and labeled in compliance with CE mark certification requirements. The
manufacturer will supply a Declaration of Conformity as required.