6
To modify the residual time, operate as indicated:
6.2.1
Press and release the UP or DOWN key again to modify the time value: the display will flash.
6.2.2
Do not operate for 4 s: the display will stop flashing and remain on permanently.
During blast chilling, the display shows the residual time of the blast chilling duration and the LED is
on.
Operate as indicated to stop the cycle:
7.
Hold the START/STOP key down.
During hard blast chilling, the display shows the temperature detected by the needle probe and the
LED is on.
To display the cabinet temperature, press and release the BLAST CHILLING, DEEP FREEZING or the HARD/SOFT key;
to restore the normal display, press and release the same key again or do not operate for 15 s.
When the temperature detected by the needle probe reaches the hard blast chilling phase end temperature, the device
automatically passes to blast chilling mode.
During blast chilling, the display shows the temperature detected by the needle probe and the
LED is on.
To display the cabinet temperature, press and release the BLAST CHILLING key; to restore the normal display, press
and release the BLAST CHILLING key again or do not operate for 15 s.
If the temperature detected by the needle probe reaches the blast chilling end temperature within the maximum blast
chilling duration, it means that blast chilling has been completed successfully, the device will automatically pass to
storage and the buzzer will be activated for the period of time established.
Press and release a key to silence the buzzer.
During storage, the display shows the temperature detected by the cabinet and the LED is on.
If the temperature detected by the needle probe does not reach the blast chilling end temperature within the
maximum blast chilling duration, blast chilling will not be completed successfully but will continue, the
LED will
flash and the buzzer will be activated.
Press and release a key to restore normal display and to silence the buzzer.
To display the cabinet temperature, press and release the BLAST CHILLING key; to restore the normal display, press
and release the BLAST CHILLING key again or do not operate for 15 s.
When the temperature detected by the needle probe reaches the blast chilling end temperature, the device
automatically passes to storage in the same way as illustrated previously.
2.4
Deep freezing and storage
The temperature-controlled deep freezing and storage cycle is divided into the following two phases:
-
deep freezing
-
storage
On conclusion of a phase, the device passes automatically to the next.
Operate as indicated to start the cycle:
1.
Make sure the device is in the "on" status.
2.
Make sure that the keyboard is not locked and that no procedure is in progress.
3.
Press and release the DEEP FREEZING key: the LED, the
LED, the HARD LED and the
LED will
flash.
press and release the DEEP FREEZING key to start the cycle with timed-control: the LED, the
LED, the
HARD LED and the LED will flash and the
LED will switch off (press and release the DEEP FREEZING
key again to start the cycle with temperature-control).
4.1
the display will show the work set-point during deep freezing;
If it has been decided to start the cycle with timed-control, the display will show the duration of time-controlled
deep freezing;