3
Operate as follows to exit the procedure:
5.
Press and release the BLAST CHILLING key or do not operate for 15 s: the display will show “Pb1” again.
6.
Press and release the UP or DOWN key until the display shows the magnitude "The display" or do not operate
for 60 s.
1.5
Display of the temperature detected by the needle
probe
Operate as follows:
1.
Make sure that the keyboard is not locked and that no procedure is in progress.
2.
Hold the DOWN key for 1 s: the display will show the first label available.
3.
Press and release the UP or DOWN key to select “Pb2”.
4.
Press and release the BLAST CHILLING key: the display will show the temperature detected by the needle
probe.
Operate as follows to exit the procedure:
5.
Press and release the BLAST CHILLING key or do not operate for 15 s: the display will show “Pb2” again.
6.
Press and release the UP or DOWN key until the display shows the magnitude "The display" or do not operate
for 60 s.
1.6
Defrosting activation in manual mode
Operate as follows:
1.
Make sure the device is in the "on" status or a storage is in progress.
2.
Make sure that the keyboard is not locked and that no procedure is in progress.
3.
hold the DEFROSTING key down for 4 s: the LED will switch on.
1.7
Locking/unlocking the keyboard
Operate as follows to lock the keyboard:
1.
Make sure no procedures are in progress
2.
Hold the DOWN key and the START/STOP key down for 1 s: the display will show “Loc” for 1 s.
The following operations will not be allowed if the keyboard is locked:
-
switching the device on/off
-
cabinet temperature display (with the procedure given in paragraph 5.4)
-
display of the temperature detected by the needle probe (with the procedure given in paragraph 5.5)
-
evaporator temperature display
-
condenser temperature display
-
defrosting activation in manual mode
-
operating cycle start-up/cut-off
-
switching on UV light for sterilisation cycle
-
heating the needle probe
-
displaying information relative to the HACCP alarms
-
deleting the information relative to the HACCP alarms
-
displaying compressor operating hours