7.2 TEMPERATURE CONTROL
17
Temp.-probe
Developer Temp.
Heating/Cooling
BleachFix Temp.
Heating/Cooling
Sensorbar
Incomming media area
Replenishment
Bus-System
Measurement
Action
Probes positioned under solution levels precisely monitor all solution tank temperatures.
These temperature probes are continuously supplying information to the microprocessor
on actual solution temperatures within the tanks. The microprocessor then compares these
actual temperatures to the required programmed ”set” temperatures and controls the rele-
vant heaters/cooling systems accordingly.
Position of the temp.-probes:
NOTE:To transfer this information, a BUS-SYTEM is installed.
COLOUR CODE
DEV(T1)......................Yellow
BF (T2)........................Blue
Dry (T3).......................Red
DEV
BF
DRY