AN 06/2003
page 25
11.5 Manual Replenishment
It could be necessary to inject fresh chemistry manually by hand. To do that, follow
the procedure underneath:
Press
5
one time, with
6
,
move the cursor to
REP
,confirm that point with
7
.
you will see:
To start a replenishment cycle for tank1:
Use
6
,
to move the cursor to REP1 , press
7
.
one time, this will spent 100ml fresh developer
chemistry to the DEV-tank. To add additional 100ml, press again
7
.
and so on......
The same procedure is valid for Tank 2 and of course to Tank3. Use
6
to jump to REP2 .
With
8
you can scroll trough the next page, in order to start REP3 in same way as described
above. After you finished the manual replenishment, use
4
to jump back to the main page.
xy% Done
is the progress indicator. It means xy% of the developing process is complete.
When it reached 100%, the unit will stop the processing mode and will go to standby.
T1=35.0ºC
confirms about the actual measured temperature in tank1. The value in the
brackets is the programed temperature. The same indication is valid for:
Tank 2 (T2)........Bleachfix 35°C
Tank 3 (T3)........Dryer 50°C
Rep1, Rep2 and Rep3
are the replenishment rates for the current program for the
corresponding tank. All this values are given by chemistry / film manufacturers.
Tank1 time
, is the time when the material is in the developer section in seconds.
Dry to dry
is the length of the complete processing cycle (leading edge in to leading edge out).
Speed
is the linear speed of the media inside the processor (cm/min).
Rep1 100 ml ON
Rep2 0 ml OFF
Rep3 100 ml OFF