AN 06/2003
page
The "Monitor Programme" is used to check and calibrate several important parameters
within the processor. Press the bottum
5
, you will see:
, move the cursor by
using
6
to
Monitor
and confirm with
7
DDBFS1S2S3DD
--------
This represents the processor,: the first two DD represent the Developer section, BF -
the Bleachfix , S1 - the Superstabi1, S2 - the Superstabi2, S3 - the Superstabi3 and the last
DD is the dryer section.
The dashes on the second row indicate the position of the material.
The following indications are:
Start P1 Use
Rep Monitor
30
11.14 MONITOR MENUE
Motor Off / On
Motor is
On
or
Off
Speed 42 024
19
speed
001
pulse confirming from the motor tacho
Normal s-bar
Type of sensorbar
Area=0.0000 sqm.
Displays the film area entering the processor
That means sensor 3 and 2 are occupied
That means sensor 1 and 0 are occupied
the first page looks like this:
S-bar: ---------
This feature is used to check each sensor of
-----------
the sensor-bar. The COLENTA 56 RA-7MW is
equipped with 6 sensors. To check the sensors, use
the following instructions:
-put a small film under the sensorbar (don’t feed into the
processor)
-move the film accros the witdth of the sensorbar
-at the same time have a look to the display
S-bar: ---------
---------10
S-bar: ---------
-------32--
and so on......