Advanced Settings
The advanced settings screen is for setting up preferences for the PLT 60 such as units of measure,
thumper time and more. If dry ice begins clumping in the hopper, the thumper frequency and time
can be increased to help the flow of dry ice while blasting.
Figure 9: Advanced Settings Screen
1. To access the Advanced Settings screen:
a.
From the Home screen, use the rotary encoder dial to select settings then advanced
settings.
2. To change the units of measurement (A):
a. Using the rotary encoder dial, navigate to units and press to select.
b. Toggle between US standard (LB | PSI | °F) or metric (KG | BAR | °C) and press to
select.
3. To change the thumper and ramrod settings (B, C, D and E):
a. For thumper and ramrod time (B), use the rotary encoder dial to adjust the timing in
between the thumper/ramrods (in seconds).
b. The SureFlow hopper on/off (C) operates based on the vibrator on/off values when
dry ice is detected at the second mid hopper level sensor.
c.
For vibrator on (D), adjust the number of seconds the hopper will vibrate. For vibrator
off (E), adjust the number of minutes between vibrations.