21
Follow the instructions below to set up the PLT 60:
1.
Set the parking brake by pressing down (lift to release).
2.
Attach the blast hose and control cable to the PLT 60.
3.
Attach an applicator to the blast hose and control cable.
4. Attach a nozzle to the applicator.
5. Connect the static ground reel to the target surface.
6.
7. Attach the air supply hose to the front of the PLT 60.
Maximum air supply pressure is 250 psi (17.2 bar)
8. Turn the air supply on and allow the air hose to pressurize.
The PLT 60 automatically bleeds pressure when the e-stop is engaged,
the unit is powered off, and/or is disconnected from its power source
9.
Once the PLT 60 is set up, go to “Starting the PLT 60” on page 22.
Figure 6: Setting Up the PLT 60