27
3.
On the control panel, press the power button to turn the PLT 60 OFF (the power button will
turn red).
4.
Turn off the compressed air supply. The PLT 60 will automatically bleed any remaining
pressure.
There is no need to bleed the air pressure from the PLT 60. The PLT
60 automatically bleeds air pressure during proper shut down. It also
automatically bleeds for approximately two seconds every 30 minutes of
trigger time during operation.
5.
When all the air pressure is bled off, disconnect the air supply hose from the PLT 60.
6. Unplug the power cord from the PLT 60.
7.
If transporting the PLT 60 to a different location, disconnect all cables and hoses from the
PLT 60 first and stow them on retractable hooks.
8.
If storing the PLT 60, disconnect all cables and hoses and stow them on retractable hooks.
Store the PLT 60 in a dry space free of dirt and debris. Keep out of direct sunlight.