PROGRAMMING
®
None
With this option it is not possible to carry out the data recording.
If in the “10.3.1 Device” menu item the “None” option is selected, the successive items of
the same menu (10.3.2-5) will be inhibited.
EVADTS->IRDA
With this option the data expressed according to the EVA-DTS protocol specifications can
be recorded by the Aeterna Coin Mechanism by means of the IR interface integrated in the
Validator/Separator group. By enabling this function on the first line of the Coin
Mechanism display will appear the IR symbol (see para. 1.5.2. “Operation conditions”).
EVADTS -> IR PORT
This option is used when an IR PORT Module is connected to the Aeterna Coin Mechanism to
carry out the data recording according to the EVA-DTS protocol specifications. By enabling
this function on the first line of the Coin Mechanism display will appear the IR symbol (see
para. 1.5.2. “Operation conditions”).
EVADTS -> PC
This option is used when to the Coin mechanism is connected the harness for serial
communication to PC, the PC programming interface for Systems and Validators in
"Parameter programming" mode, and any recording device in EVA-DTS which uses the RS232
standard to carry out the data recording according to the EVA-DTS protocol specifications.
By enabling this function on the first line of the Coin Mechanism display will appear the
PC
symbol (see para. 1.5.2. “Operation conditions”).
Note: by enabling a peripheral for data recording, the possibility of carrying out any
operation by means of EasyCoinProfit is excluded. This condition is signalled on the
display with the IR or PC symbol (see para. 1.5.2. “Operation conditions”). By pressing
the Esc + Enter keys on the programming keypad it is possible to disable momentarily the
data recording and to enable the operations on PC by means of EasyCoinProfit (see
para. 3.1.1. “Programming keypad”). In this case the IR or PC symbol will not be shown on
the display. To restore the starting situation it is necessary to switch off the Coin
Mechanism and then switch it on again.
Printer
This option is used when a serial printer is connected to the Coin Mechanism for carrying
out the data recording (see para. “10.3.7 Printer Recording”). By enabling this function on
the first line of the Coin mechanism display will appear the symbol of the printer (see
para. 1.5.2. “Operation conditions”).
10.3.2 IRDA Password
This menu item permits to set a password for enabling the transmission of the IR data; it
consists of 8 hexadecimal digits (accepted characters: 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, A, B, C, D, E,
F). As a default the password is set at 00000000. In this latter condition the Coin Mechanism
acquires any password from the data recording palmtop terminal.
<
Enter the first number of the Password by using the
<< >>
keys;
press the
Enter
key to confirm the data and pass to the following one.
10.3.3 Automatic Delete
This function permits to carry out the data automatic delete after the EVA-DTS recording car-
ried out. The reset occurs after the first event (key, bill or coin insertion or sale request).
As a default the data set is NO.
IRDA Password
[
00000000]