English
9. lamp installation and alignment
9.1 Lamp installation
1.
Use a suitable tool to loosen the four screws “A“ which fix the lamp holder cover at the rear of the projector.
2.
Remove the lamp holder cover “B”.
3.
Identify the lamp holder “C“ and insert the lamp correctly.
4.
Insert the lamp and gently the lamp clockwise without force it if has difficulty to rotate.
The lamp used is manufactured from quartz glass and should be handled with care; always adhere to the instructions supplied in
the lamp’s packaging. Never touch the glass directly, use the tissue provided in the lamp’s packaging. DO NOT USE UNDUE
FORCE.
5.
Replace the lamp holder cover in its original position and screw the two screws “A” back in.
WARNING !
• Never use undue force if the procedure becomes difficult.
• Never put pressure on the glass of the lamp.
• Never touch the glass of the lamp with bare hands.
The
Infinity Spot S
utilises the Philips MSR GOLD 300/2 FastFit with PGJX28 base lamps. The use power is 300W.
These lamps are available at your
Coemar’s
distributor or service centre..
The fixture’s internal temperature can reach 250° C after 5 minutes, with a maximum peak of 350°C; ensure that the lamp is cold
prior to attempting removal. The fixture should be allowed to stand and cool for 10 minutes prior to its removal.
The lamps are part of the mercury vapour family of discharge lamps and must be handled with great care. The lamp operates at high
pressure, and the slight risk of explosion of the lamp exists if operated over its recommended life. We recommend, therefore, that the
lamp be replaced within the manufacturer’s specified lamp life.
Lamp
Philips MSR Gold 300/2 Fast Fit
Coemar code
105820
Wattage range
300 W
Lumen output at 300 W
22000 Lm
Colour temperature
8000 °K
Base
PGJX28
Approximate lamp life
750 Hrs
WARNING !
Disconnect the unit from main power prior to attempting lamp’s installation or replacement.
Make sure the unit is sufficiently cooled.
20