7.1. Lamp Replacement
Disconnect mains before servicing!
The lamp should be replaced at the end of its service life to avoid possible lamp
explosion and damage to the
Flex
fixture. The service life for the MSR-2000/SA is 750 hours. It is suggested that you
use the
HOUR
/
LIFE
feature in the
MEAS
menu to keep track of lamp hours and replace the lamp when the display
shows
OLD.L
. Always wear safety glasses when servicing the lamp. The lamp gets
extremely
hot. Allow the fixture to
cool before servicing the lamp. Follow the procedure for lamp installation and optimization in the accompanying
Quick
Start
manual. Always optimize the lamp positioning when installing a new lamp.
7.2. Fuses
Disconnect mains before servicing!
Replace fuses only with the same type and rating.
Flex
uses three fuses, two
accessible externally as shown in Fig. W10 and another internal fuse on the switching power supply. To replace the
switching supply fuse remove the base covers as in Figure 11A, followed by removing the 4 supply retaining screws on
the bottom of the fixture as in Figure 11B. Locate the switching supply from the top as shown in Fibure 11C and remove
it from the fixture base. Remove the blown fuse and Figure 11D. Check for any indications of damage to the switching
supply and wiring before replacing fuse. Reinstall the supply.
Figure W10 Main Fuses
Figure W11A - Removing Base Covers
Figure W11B - Removing Switching Supply
Figure W11C- Removing Switching Supply
Figure W11D - Changing Switching Supply Fuse
Main:
190-250V(
)
50/ 60Hz
Autosensing
Pow er
T16A
T16A
Section 7: Maintenance