Cabling
The mains cable provided is thermally resistant, complying to the most recent international standards.
NB:
In case of cable replacement, similar cable with comparable thermal resistant qualities must be used exclusively (cable 3x1.5 ø exter-
nal 8 mm, rated 300/500V, tested to 2KV, operating temperature -40° +180°
coemar
cod. CV5309).
Mains connection
ColourCyc 250 LX
can operate at voltages from 100V-115V-208V-230V-240V at 50 or 60Hz (operating voltage and frequency
can be selected as described in section 5 and 18 of this manual). Prior to connecting the unit to your mains supply, ensure that the
model in your possession correctly matches the mains supply available to you.
For connection purposes, ensure your plug is of a suitable rating:
at 230 V: 2 Amps peak, 1.6 amps in normal operation
at 115 V: 4.2 Amps peak, 3.2 amps in normal operation
Locate the mains cable which exits the base of the unit and connect as shown below:
Protection
The use of a thermal magnetic circuit breaker is recommended for each
ColourCyc 250 LX
.
A good earth connection is essential for the correct operation of the fixture. Strict adherence to regulatory norms is strongly recom-
mended.
A good earth connection is absolutely essential for the ColourCyc 250 LX to operate correctly. Never install the fix-
ture if the yellow/green earth cable is not connected.
massa/ground
neutro/neutral
fast/live
marrone - brown
blu - blue
giallo/verde - yellow/green
alimentazione
main
7. Mains connection
7
English