ColourCyc 250 LX
is able to operate via DMX 512 signal. Connection should be as described as in section
”8.2 Operation via
DMX 512 signal”
.
If the instructions in this manual have been carried out to this point, the 6 channels of your
DMX 512 controller will have con-
trol over all the functions of the ColourCyc 250 LX
as shown in the following table.:
c h a n n e l
f u n c t i o n
type of control
e f f e c t
d e c i m a l
1
d i m m e r
step
closed
0-7
proportional
from close to open
8-255
2
S h u t t e r , S t r o b e
step
Shutter closed
0-9
proportional
Synchro strobe-effect from slow to fast
10-127
step
Shutter open
1 2 8 - 1 3 0
proportional
Random strobe-effect from slow to fast
1 3 1 - 2 4 8
step
Shutter open
2 4 9 - 2 5 5
3
c o l o u r s
step
Open/white
0-24
step or proportional depending on
channel 3
colour 1
24-49
step or proportional depending on
channel 3
colour 2
50-74
step or proportional depending on
channel 3
colour 3
75-99
step or proportional depending on
channel 3
colour 4
1 0 0 - 1 2 7
proportional
Forwards rainbow effect from fast to slow
1 2 8 - 1 9 0
step
No rotation
1 9 1 - 1 9 2
proportional
Backwards rainbow effect from slow to fast
1 9 3 - 2 5 5
4
colour mode
step
colours (channel 3) steps
0-127
step
colours (channel 3) proportional
1 2 8 - 2 5 5
5
A u t o f u n c t i o n
step
No effects
0-9
proportional
Auto program 1 (color sequence without white) speed from fast to slow
10 61
proportional
Auto program 2 (full color sequence) speed from fast to slow
62-113
proportional
Auto program 3 (color sequence with half color) speed from fast to slow
1 1 4 - 1 6 5
proportional
Auto program 4 (color sequence including continuos rotation, speed from
fast to slow)
1 6 6 - 2 1 7
step
Random program
2 1 8 - 2 4 0
step
All programs
2 4 1 - 2 5 5
6
L a m p o n / o f f / r e s e t
step
Park (no function)
0-10
program wait time control step
lamp off
11-30
step
all motor reset (only once)
31-45
step
color reset (only once)
46-60
step
Program stop
61-80
proportional
Selected auto-program pause time control (1 sec/5 min)
81-241
step
lamp on
2 4 2 - 2 5 5
Dip-switches can inhibit lamp off function
note 1: lamp on/off and reset have a delay time of 6 second to prevent accidental activation.
note 2 :on/off lamp mode is not affected unless an opposite value is received
note 3 :Dip-switch "motor calibration" ON change channel 4 and 5 function
note 4 :Dip-switch "shutter/strobe inhibit" ON lose channel 2 and 4 function
11. Operating via DMX 512 signal
12
English