Victory 3_en.pdf http://en.codelight.com.cn
10
The selected addresses will show in pink if they had been used. If you continue to press
[Confirm]
in this case or
input the used number of DMX line and address, the address of the selected fixture can be changed successfully but
the fixtures that previously used/included those addresses will be suspended. You have to patch them again.
3.5.
Setup RDM Devices
The function allows the controller to interrogate the practical fixtures. Then it can patch itself to match the existing
DMX addresses. You can also remotely change the modes and other settings on the practical fixtures.
Note: Fixtures must be equipped with RDM for the function to work.
If you have connected with DMX buffers or splitters, they must be RDM enabled. Otherwise they will block the
information being sent back to the controller.
Press
[RDM Discover]
to start searching. All RDM supported fixtures will be listed here. Select the fixture and press
[RDM Info]
to look over its details.
3.5.1.
Remotely Setup Devices
We can also remotely change the address on the practical fixture.
1>
Select the fixture on the list;
2>
Press
[DMX Start Address]
;
3>
Enter the number of the DMX address to be changed, then press
[Enter]
;
1
3
2
4